background image

USB-Isolator U

ser’s Manual              

                

_________________________________________________________________________________ 

 

_______________________________________________________________________________________ 
 

 

 
 

 

Fully Isolated

 power and I/O circuits for safety and increased noise 

immunity. 

 

 

CE and FCC Compliant

.  Designed to meet and exceed EN61000 

specifications. 

 

 

High retention USB connectors

 provide minimum withdrawal force of 

15 Newtons. 

 

 

USB bus powered

 and no need for external power. 

 

 

USB Cable

 

Included

,  1 meter USB cable (Type A to Type B). 

 

 

USB 2.0 compatible

 

 

Changeable Data Rate 

allows selectable full-speed 12Mbps (

Default

), 

or low-speed 1.5Mbps.

 

 

 

Wide Ambient Operation

 from -40° to 70°C (-40° to +158°F). 

 

 

Hardened For Harsh Environments

 and includes protection from RFI, 

EMI, ESD, EFT, & surges.  Has low radiated emissions per CE 
requirements. 

 

 

Power LED

 provides power indication and overload indication. 

 

 

Reset Push Button 

is a

 

useful feature for reinitializing peripherals 

without unplugging cables. 

 

 

Built in Current Limiting with Auto Retry 

prevents damage to isolator 

and connected USB devices.

 

 

 

Small, compact and rugged housing design. 

 

 

Easy to install

 with existing equipment. 

 

 

No special drivers required. 

 

 
 

OVERVIEW 
 

Key Features  

Содержание Red-USB Iso

Страница 1: ...Red USB Iso USB Isolator User s Manual Ausgabe May 2011...

Страница 2: ...er USB cable Type A to Type B USB 2 0 compatible Changeable Data Rate allows selectable full speed 12Mbps Default or low speed 1 5Mbps Wide Ambient Operation from 40 to 70 C 40 to 158 F Hardened For H...

Страница 3: ...esponding to 137mA out load Both signal lines are equipped with common mode filters and include transient protection USB is set to full speed 12 Mbps but can be jumped to low speed 1 5 Mbps for legacy...

Страница 4: ...ice has been connected to the computer The power LED of the isolator should be ON and not blinking At this point you are ready to begin talking to your connected device TIP If your PC fails to detect...

Страница 5: ...closure and this requires handling at an ESD safe work station Warning We do not recommend that you do this in the field as it invites potential damage to sensitive internal circuitry 1 Open enclosure...

Страница 6: ...ot communicate with device connected through the Isolator Your computer does not support the peripheral Your device does not support 12Mbps Try changing internal jumpers to low speed see page 5 You do...

Страница 7: ...discharge to the enclosure port per IEC61000 4 2 Radiated Field Immunity RFI 10V M 80 to 1000MHz AM and 900MHz keyed carrier per IEC61000 4 3 Electrical Fast Transient Immunity EFT 2KV to power and 1K...

Страница 8: ...hotocopying recording or otherwise without the prior written permission of Meilhaus Electronic GmbH All the information included in this user s gide were put together with utmost care and to best know...

Отзывы: