Meilhaus Electronic

Note that the computer must be switched on first before any voltage 
is applied to the board through external circuitry.

Connecting or disconnecting any of the the board's connectors must 
always be done when all the components are powered down.

Make sure that when touching the board, or when plugging in the 
connecting cable, it is not possible for static discharges to pass 
through the board.

Ensure that the connecting cable is securely seated. The plug must be 
fully inserted into the D-sub socket, and secured using both screws. 
Only in this way can the board be expected to function properly.

1.1.2

Improper Use

Plug-on boards must never be operated outside the PC. Never connect 
the devices to electrically live parts, and particularly not to any that carry 
mains voltage.

Make sure that the external circuitry connected to the device cannot 
come into contact with electrically live parts. Connecting or disconnec-
ting any of the the  connectors must always be done when powered down.

1.1.3

Unforeseeable Misuse

The device is not suitable for use as a child's toy, for domestic purposes 
or under adverse ambient conditions (such as in the open air). The user 
must take appropriate precautions to avoid unforeseeable misuse. 

Содержание ME-5000 series

Страница 1: ...Meilhaus Electronic Manual ME 5001 1 1E Plug on Board for ME 5000 series with up to 48 Digital I Os alternatively Frequency Measurement and Pulse Generator...

Страница 2: ...s Electronic assumes no responsibility for its use any infringements of patents or other rights of third parties which may result from use of this manual or the product Meilhaus Electronic assumes no...

Страница 3: ...2 3 Fitting the Plug on Board 12 3 Hardware 15 3 1 Block Diagram 15 3 2 ME 5001 cPCI PCIe 16 3 3 Digital Input Output 17 3 3 1 Digital Inputs 18 3 3 2 Digital Outputs 18 3 3 3 External Trigger 18 3 4...

Страница 4: ...s Page 4 Meilhaus Electronic Appendix 29 A Specifications 29 B Pinout 32 B1 25 pin D Sub ST1 33 B2 Additional Sockets ST2 ST3 34 C Accessories 35 D Technical Questions 36 D1 Hotline 36 D2 Service addr...

Страница 5: ...boards of the ME 5000 series require a base board of the ME 5000 series and will be plugged onto these and extend the functio nality of the base boards Depending on the PC platform the plug on board...

Страница 6: ...into the D sub socket and secured using both screws Only in this way can the board be expected to function properly 1 1 2 Improper Use Plug on boards must never be operated outside the PC Never connec...

Страница 7: ...h the help of the following list Your package should contain the following parts 48 bit digital I O board used as a plug on board for the base boards of the ME 5000 series Manual in PDF format on CD D...

Страница 8: ...ailable for measuring the frequency and duty cycle of rectangular signals max 5 5 MHz Pulse generator The concept of the configurable subdevices allows subdevice 1 to be employed as a rectangular wave...

Страница 9: ...on page 23 Interrupt For interrupt handling in the bit pattern change mode see chapter 4 2 on page 27 Customer specific versions of the firmware are available on request 1 4 System Requirements The M...

Страница 10: ...Rev 1 1E Manual ME 5001 Introduction Page 10 Meilhaus Electronic...

Страница 11: ...C Temp Meilhaus ME iDS Use the Meilhaus Intelligent Driver System ME iDS for programming your new data acquisition hardware For installation and operation of the driver system please follow the docume...

Страница 12: ...order to be able to insert the plug on board Here you should observe the procedure as described in the manual for your PC system 2 Make sure that electrostatic discharges cannot take place through the...

Страница 13: ...Manual ME 5001 Rev 1 1E Meilhaus Electronic Page 13 Initial Operation Diagram 1 Fitting the plug on boards...

Страница 14: ...Rev 1 1E Manual ME 5001 Initial Operation Page 14 Meilhaus Electronic...

Страница 15: ...he base board Base Board ME 5001 RT Logic level selectable 3 3 V 5 V Buffer Buffer Buffer Buffer RT DIO_0 7 FI_0 7 DIO_8 15 FO_0 7 DIO_16 23 DIO_24 31 RT RT DIO_32 39 DIO_40 47 Subdevice 0 Subdevice 1...

Страница 16: ...n the following chapters you will learn more about the external wiring of the individual subdevices Chapter 4 from page 21 describes the ope ration modes and the programming 3 2 ME 5001 cPCI PCIe Diag...

Страница 17: ...e direction of the ports is defined by software After powering up all the ports are configured as inputs Diagram 4 Wiring of digital inputs outputs Please read chapter 4 1 1 from page 23 for programmi...

Страница 18: ...ed directly to the PC See chapter 4 2 on page 27 3 4 Frequency Input Output The concept of the configurable subdevices of the ME 5000 series gives you the option of using individual subdevices with an...

Страница 19: ...put 3 5 External Interrupt If required you can also monitor the bit pattern of the digital inputs The bit pattern change mode is available on the ME 5001 As soon as the specified event occurs an inter...

Страница 20: ...the subdevices 0 3 The termination circuits are effectively protected against overload by the combination of current limiting and thermal shutdown with automatic return to service 3 6 2 Logic Level M...

Страница 21: ...under www meilhaus com download Other details such as the assignment of the subdevices and device specific arguments may be found in the help file in the help file format under Windows chm which you...

Страница 22: ...he bit pattern change mode see chapter 4 2 1 starting on page 27 Subdevice type subtype I Os ID of the configuration Subdevice 0 DIO FI Digital input output DIO Single 8 bit bi directional 0 Frequency...

Страница 23: ...g mode All subdevices are of type ME_TYPE_DIO subtype ME_SUBTYPE_SINGLE The configuration is done separately for each subdevice Diagram 6 Digital input output in single operating mode Please observe t...

Страница 24: ...iDS manual and the ME iDS help file chm carefully prior to programming You can open both of these documents through the ME iDS Control Center or through the Windows Start menu Two variables are introd...

Страница 25: ...figures for the ME 5001 are Tmax asym 32 5 s 0 03 Hz Tmax sym 65 s 0 015 Hz The wiring of the frequency inputs outputs can be found in chapter 3 4 on page 18 4 1 2 1 Frequency Measurement With the fr...

Страница 26: ...tput rectangular signals with a variable duty cycle at frequencies of up to 5 5 MHz and with a resolution of 1 tick On the ME 5001 all 8 pulse generator channels FO_0 7 are addressed as subdevices of...

Страница 27: ...manual and the ME iDS help file chm for the procedure You can open both of these documents through the ME iDS Control Center or through the Windows Start menu 4 2 1 Bit pattern Change In the bit patt...

Страница 28: ...function meIOIrqStart bit 2 is monitored for a fal ling edge and bit 7 for a rising edge A rising edge now is to arrive at bit 7 so that an interrupt is issued and in the interrupt status value bit b2...

Страница 29: ...Subdevice 0 5 16 bit bidirectional Operating modes Single Software triggered reading writing Interrupt Monitoring the digital ports for a change in the bit pattern External trigger inputs DIO_0 47 Ex...

Страница 30: ...1 ns 5 5 MHz 32 5 s 0 03 Hz 65 s 0 015 Hz Duty cycle Variable depending on T Measurable in steps of 1 tick Resolution 1 tick 15 15 ns Accuracy 15 15 ns Operating modes Single Measured quantity criteri...

Страница 31: ...via base board 3 3V 5V Current consumption additional to base board 0 50 0 9A full load Board dimensions without mounting bracket and connector base board requires its own slot 120mm x 100mm Connectio...

Страница 32: ...DIO_16 23 Digital input output subdevice 2 DIO_24 31 Digital input output subdevice 3 DIO_32 39 Digital input output subdevice 4 DIO_40 47 Digital input output subdevice 5 FI_0 7 Frequency measuring...

Страница 33: ...s only possible after appropriate configuration using ME iDC The other pins of the relevant subdevice can then no longer be used for digital input output n c n c FI_1 DIO_1 FI_3 DIO_3 FI_5 DIO_5 FI_7...

Страница 34: ...cable red marked line is connected on to the IDC socket ST2 resp ST3 as shown in diagram 12 Diagram 12 Connecting the additional sockets ST2 ST3 20 pin IDC socket for ST2 and ST3 Pin Labeling ST2 3 P...

Страница 35: ...7 to a 25 pin D Sub female connector E g for connecting the ME 63Xtend or ME UB series ME AK D2578 4000 Special connection cable for connection of the ME 63Xtend series via 25 pin D Sub female connect...

Страница 36: ...n D2 Service address If a technical error should occur with your device please contact us at the following address Meilhaus Electronic GmbH Service Department Fischerstra e 2 D 82178 Puchheim Germany...

Страница 37: ...ures 8 Frequency input output Programming 24 Wiring 18 Frequency measurement 18 25 H Hardware description 15 I Interrupt Programming 27 Wiring 19 Introduction 5 L Logic level matching 20 O Operation M...

Страница 38: ...Rev 1 1E Manual ME 5001 Index Page 38 Meilhaus Electronic...

Отзывы: