background image

 

 

Appendix 

Specification 

(Ambient temperature 25 º) 

PC-Interface 

 

Standard-PCI- resp. CompactPCI-bus (32 bit, 33

 

MHz, 5

 

PCI Local bus specification version 2.1 compliant; 

CompactPCI Specification PICMG 2.0 R3.0, 

Resources assigned automatically (Plug&Play) 

 

Voltage Outputs  

(Partly different specifications are valid for the „U-Plus“-channel – see 

separate section) 

Number of channels 

4, 8 or 16 (depends on model) 

D/A converter 

1 serial converter (500 kHz) per channel  

Resolution 

16 bit 

Output range 

±10 V 

Output current 

Without external power supply: depends on 

the number of assembled resp. used chan-

nels: 

 

channels 

I

max

 per channel 

 

15 mA 

 

15 mA 

 

12 

10 mA 

 

16 

3 mA 

 

With external power supply (±15 V) only in 

connection with options „Island channels“ 

and „High Current“: max. ±15 mA per 

channel) 

Ext. power supply 

±15

 

V (optional); current per channel: 7

 

mA 

+ load (max. ±15 mA) 

Settling time (DAC) 

max. 2

 μ

s at full-scale (-10

 

V        +10

 

V) 

 

 

 

Содержание 16 ME-6200x/9

Страница 1: ...Meilhaus Electronic Manual ME 6000 Series 3 0E ME 6000 6100 6200 6300 16 bit D A Conversion Board with up to 16 Channels and Electrical Isolation optional Island Channels...

Страница 2: ...ote The information contained in this manual has been reviewed with great care and is believed to be complete and accurate Meilhaus Electronic assumes no responsibility for its use any infringements o...

Страница 3: ...ftware Installation 10 2 2 Test Program 10 3 Hardware 11 3 1 Block Diagrams 11 3 2 D A Section 12 3 2 1 Notes for Wiring 13 3 2 2 Electrical Isolation 14 3 2 3 Island Channels 15 3 2 4 Option High Cur...

Страница 4: ...B1 D Sub Connector ST1 26 B1 1 ME 6000 6100 26 B1 2 ME 6200 6300 27 B2 Auxiliary Connector ST2 28 C Accessories 29 D Technical Questions 31 D1 Hotline 31 E Index 32...

Страница 5: ...noted 1 1 Important Notes 1 1 1 Use in Accordance with the Requirements The PC boards of the ME 6000 series are designed for acquisition and output of analog and digital signals with a PC Depending on...

Страница 6: ...Express or CompactPCI bus may not be taken into operation outside of the PC Never connect the devices with voltage carrying parts especially not with mains voltage As power supply for the USB models o...

Страница 7: ...n Driver software on CD DVD Additional mounting bracket ME AK D25F S cPCI for PCI resp CompactPCI slot 25 pin D Sub male connector 1 3 Features ME 6000 6100 PCI CompactPCI 16 bit D A Converter Model T...

Страница 8: ...With that accuracies better than 1 are possible Independent of the total number of channels you can use the first 4 channels for signal curve output on the ME 6100 6300 Each of the 4 channels has its...

Страница 9: ...C with a free standard PCI PCI Express resp CompactPCI slot 32 bit 33 MHz 5 V The board is supported by the Meilhaus Electronic Intelligent Driver System ME iDS 1 5 Software Support The ME series 6000...

Страница 10: ...e please unpack the software before installing the board First choose a di rectory on your computer e g C Temp Meilhaus ME iDS Use the Meilhaus Electronic Intelligent Driver System ME iDS for programm...

Страница 11: ...DIOs ME 6000 16 16 D A channels 10 V UOUT_0 15 16 DIOs ME 6100 4 4 D A channels 10 V UOUT_0 3 with FIFO 16 DIOs ME 6100 8 8 D A channels 10 V UOUT_0 7 4 of them FIFO UOUT_0 3 16 DIOs ME 6100 16 16 D...

Страница 12: ...ME 6300 9 8 D A channels 10 V x 0 7 4 of them with FIFO 1 U Plus channel UOUT_8 16 DIOs Depending on the version not all functional groups available 3 2 D A Section Depending on model the boards of t...

Страница 13: ...nnels ME 6200 ME 6300 is from 0 V to 50 V 1LSB if the standard output buffer is used 3 2 1 Notes for Wiring Attention After power up the standard D A channels output 10 V After starting the driver the...

Страница 14: ...be not connected 3 2 2 Electrical Isolation All D A channels of the board are electrically isolated by opto cou plers from PC GND I e GND_0 15 are connected with one an other and have a common ground...

Страница 15: ...each channel GND_0 15 with the appro priate GND of your external application Further on every island channel requires an independent symmetrical power supply of 15 V 22 mA per channel for Imax 15 mA...

Страница 16: ...xternal low noise power supply of 15 V 22 mA per channel for Imax 15 mA and a change to your hardware please contact our service department see page 31 3 2 5 External Trigger D A Section The D A chann...

Страница 17: ...nels depending on model can be started from any trigger input 3 3 Digital I O Section All boards of type ME 6000 6100 with hardware version 2 6 or higher as well as all boards of type ME 6200 6300 pro...

Страница 18: ...hat the voltage levels of the digital input output wiring be within the TTL level limits see specifications on page 22 and that a reference to PC ground PC_GND be made The maxi mum output current is I...

Страница 19: ...ile format under Windows chm which can be accessed via the ME iDS Control Center in the info area of the task bar as a rule in the lower right corner of the screen or via the Windows start menu If you...

Страница 20: ...ernal digital trigger Trigger edge trigger event on falling rising or any edge A programmable counter serves as timer which is configured by the trigger structure meIOStreamTrigger The 32 bit counter...

Страница 21: ...t output of single digital values is done in operation mode Single Each digital port is accessed as a subdevice of type ME_TYPE_DIO subtype ME_SUBTYPE_SINGLE Note the order of operation as described i...

Страница 22: ...section Number of channels 4 8 or 16 depends on model D A converter 1 serial converter 500 kHz per channel Resolution 16 bit Output range 10 V Output current Without external power supply depends on t...

Страница 23: ...k values per channel Sample Rate max 500 kS s D A Timer programmable from 2 s up to 130 s in steps of 30 30 ns External Trigger channel 0 3 Voltage level typ 5 V Input current IF 7 5 mA IF 10 mA Refer...

Страница 24: ...on Power consumption at 5 V 16 D A channels without ext load With electrical isolation max 3 6 A With island channels max 1 2 A Load for VCC_OUT max 200 mA Physical size PCI 174 mm x 99 mm without mou...

Страница 25: ...HC and Island Channels AO_TRIG_x digital trigger input for each D A channels 0 3 DIO_Ax digital I O port A DIO_Bx digital I O port B GND_ Common ground for all D A channels Electrical isolated from P...

Страница 26: ...B1 D Sub Connector ST1 B1 1 ME 6000 6100 Note the warning on page 25...

Страница 27: ...B1 2 ME 6200 6300 Note the warning on page 25...

Страница 28: ...from 20 pin IDC connector to mounting bracket with 25 pin D Sub female connector comes with the board Attention When connecting the mounting bracket make sure to plug in pin 1 of the flat ribbon cabl...

Страница 29: ...ith single shielded lines per channel As accessory we provide the special connector cable ME AK D78 6000M OE length 1 m ME AK D78 6000M OE Special connector cable from 78 pin D Sub male connector to 1...

Страница 30: ...n by ST2 with addi tional mounting bracket ME AK D25F S and special connection ca ble ME AK D2515 4000 ME AK D25 HQ 1 High quality cable with different lengths 25 pin D sub male to fe male 1 1 contact...

Страница 31: ...ail support meilhaus de Download Server and Driver Update To download current driver versions for Meilhaus Electronic devices as well as manuals in PDF format please go to www meilhaus org driver Serv...

Страница 32: ...ware 11 Hotline 31 I Important Notes 5 Improper Application 6 Introduction 5 Island Channels 15 O Option High Current 16 P Package Contents 7 Pinout 25 Programming 19 S Simple Input Output 21 Single V...

Отзывы: