Emptying can take place.
•
After emptying, the tank vehicle has to be vacuumed for approx. 2 min.
•
Set (key) switch "Acknowledge connection" after emptying to position 0.
•
Disconnect tank emptying hose from "food waste" tank wagon connection.
•
Disconnect the pendulum gas hose at the "pendulum gas" hose connection.
9.5
Operation of tank emptying process, collection tank com-
pression-proof without pendulum gas line
- Circulation is activated after logging in (turning on the key switch)!
- Circulation should take place for at least 15 min.!
- Circulation is deactivated by selecting a suction process (pressing the selection
key) "With compressed air" or :"Without compressed air"!
•
(Key) switch "Acknowledge – connection" set to position 1. Pressing
"Acknowledge – connect" activates circulation!
•
Tank emptying – connect hose.
•
Option!
"Start without compressed air" - only suction power from the disposal vehicle !
"Start with compressed air" - compressed air from the MEIKO unit!
•
Press the illuminated white button "Start without compressed air" or "Start with
compressed air" and the selected button is continuously lighted up.
•
If you select compressed air, wait one minute before the tank vehicle starts the
suction process.
•
The selection can be deactivated and restarted by pressing the "Stop" button!
•
Emptying can take place.
•
After emptying the suction process is started "Without compressed air" so that
the tank vehicle can vacuum.
•
Set (key) switch "Acknowledge connection" after emptying to position 0.
•
Disconnect tank emptying hose from "food waste" tank wagon connection.
•
Disconnect the pendulum gas hose at the "pendulum gas" hose connection.