43 / 62
9750359
No.
Display text
Measures/remedial action
163
Activation of automatic hood operation
performed. Restricted operation ended
when hood is operated manually.
• No action required
• Possible to continue working
200
Boiler level not reached on time during
filling
• Open the local water supply
• Check pre-filter/sieve and clean, if necessary
205
Maximum final rinse cycles insufficient
• Sort washware correctly
• Possible to continue working
212
Forced drainage due to permanently
filled boiler
• Change the water or drain the machine at least once
a day
213
Pressure booster pump or air catch de-
fective
• Check the rinse system and clean, if required
• If this message reoccurs, call a service technician
301
Lack of rinse aid
• Replace canister
• If necessary, check and clean the position of the suc-
tion lances
311
Lack of detergent
406
Advance report: cartridge nearing end of
life
• Have a replacement cartridge ready
• Replace when notification 407 appears
407
Change demineralisation cartridge
• Change demineralisation cartridge
408
Change osmosis system pre-filter
• Replace pre-filter
410
Water supply reverse osmosis module
disturbed
• Open water inlet valve
• Check pre-filter/sieve and clean or replace, if applica-
ble
421
Insufficient water in holding tank
• Open water inlet valve
• Where appropriate, call a service technician
422
Max. level not reached in holding tank
423
Water feed into holding tank insufficient
426
Osmosis membrane blocked/dirty
• Possible to continue work at limited capacity
• Check pre-filter and replace if necessary
• Call a service technician!
500
Energy optimisation active
• No action required
501
Energy optimisation active
Tank temperature not reached
• Possible to continue working
• Call a service technician!
502
Energy optimisation active
Wash time increase in tank insufficient
• Possible to continue working
• If this message reoccurs, call a service technician
503
Energy optimisation active
Temperature increase not reached
• If this message reoccurs, call a service technician
504
Energy optimisation active
Final rinse temperature not reached
• Call a service technician!
505
Energy optimisation active
Wash time increase on final rinse insuffi-
cient
• If this message reoccurs, call a service technician
892
Communication with SMART WIRE node
addr. 13
• Possible to continue working
• Call a service technician!
963
Bluetooth access error
• Confirm message
• Possible to continue working
• Call a service technician!
969
Low battery
• Confirm message
• Able to continue working at limited capacity
• Call a service technician!
971
Operating panel re-initialising
• If this message reoccurs, call a service technician
Содержание M-iClean H series