Service step
Maintenance
Cleaning works
Daily
At least once
quarterly
At least once
or twice a
year
but
every
1000 h
At least once
yearly
but
every
2000 h
VERY IMPORTANT:
Whenever any electrical components are disconnected and
reconnected, replaced or repaired, a safety test must be
conducted, at least on these components!!!
17. Visual check on the machine environment
Foaming detergents must not be used close to the machine area and not
in connection with the machine
Water treatment installation (if present)
Reverse osmosis installation (visual check); inform customers on the
necessity of installation maintenance
Demineralisation installation (visual check); inform customers on the
necessity of installation maintenance
Observe the manufacturer’s operating instructions in all cases
Air gap according to WRC (if present, i.e. for England)
Check the spray pattern for the perlator nozzle (on the water discharge)
Clean / descale the perlator nozzle (on the water discharge)
x1
Maximum suction temperature fan 0 550 056
75°C
Maximum suction temperature fan 0 550 050
75°C
x2
Pump pre-cleaning temperature
according to DIN 10510
40°C to 50°C
Detergent circulation tank temperature according to DIN 10510
55°C to 65°C
x3
Clean water rinse temperature
according to DIN 10510
80°C to 85°C
x4
Dryin temperature
according to DIN 10510
not specified (see x
1
)
x5
Minimum water quality according to the VGG
Total salt content:
max. 400
S/cm for porcelain and opal glass
max. 100
S/cm for glass
max. 80
S/cm for stainless steel (cutlery)
The service steps Servicestufen
-
must be carried out by personnel trained for this purpose.
trained operating personnel
company tradesman after instruction
trained company tradesmen or installation engineers
installation engineers trained by MEIKO
You can document the completed maintenance work on the following pages. Meiko recommends that you enter the