Page 13
CAUTION
After adjusting the height of the machine,
always check that it is level to ensure
proper operation.
3. Position each table lip-in at the machine,
as shown in Figure 3-17. Be sure to seat
the lip-in against the inner, vertical mount-
ing surface.
CAUTION
If the table lip-in extends beyond the
vertical mounting surface, and down to the
angled face of the inside of the machine,
it will not seat properly.
The lip-in should
be no more than 3/4” (19mm) in depth
to ensure correct mounting to the
machine.
4. For corner installations, check that the
sides of the front table do not prevent the
door handle from being pushed down far
enough to engage the door switch. By
pushing the handle slowly, you should
hear an audible “click” as the switch
engages.
If it is necessary to trim the table sides to
clear the handle and allow the switch to
engage, refer to Figure 3-18.
5. After the tables have been positioned
correctly, secure them to the machine
using silicone sealant.
20-1/4”
(514mm)
recommended
Turndown
lip-in
flange
3/4”
(19mm)
max.
Lip-in flange MUST
be flush against the
vertical mounting
surface
Lip-in flange MUST
NOT extend to the
angled face inside
the machine
Figure 3-17: Tabling attachment
Figure 3-18: Door handle clearance for corner installations
5”
(127mm)
2-1/2”
(64mm)
Cutout allows door
handle to be
pushed down to
engage door switch
S
ECTION
3 - I
NSTALLATION