9763258
53 / 64
13.
Electrical safety check (certificate is optional)
Carry out the visual inspection
U/H
annually
Check the protective earth conductor
U/H
annually
Insulation resistance measurement
U/H
annually
Measure current on protective earth conductor
U/H
annually
9.3
Change pre-filter on reverse osmosis module (GiO MODULE)
Dishwashing machines with reverse osmosis (GiO MODULE) contain a pre-filter
which must be changed by the operator every 6 months (for a standard membrane
(< 0.1 mg/l)) or every 3 months (for a chlorine-
resistant membrane (≥ 0.1 and ≤ 2.0
mg/l)). The spare parts pack contains a new filter, seal, label and description. A key
to unscrew the pre-filter is included in the delivery of the dishwashing machine.
A message will appear on the display when it is time to change the pre-filter (Mes-
sage no. 408 "Change pre-filter on osmosis system").
• Disconnect the dishwashing machine from both the power and water supplies.
• Provide a suitable container to drain remaining water, e.g. base drip tray.
• Thoroughly rinse the new filter cartridge inside and out with clean water.
GiO MODULE in machine plinth
1. Unscrew front panel (1) (you will need a Torx 20
screwdriver).
2. Remove the whole pre-filter (1). In some cases,
there is a recess in the casing to facilitate re-
moval of the pre-filter.
Содержание 007DWUC1M2-10
Страница 63: ...9763258 63 64 14 Notes...