9763258
47 / 64
6. Select the counter to be reset.
7. Confirm the selection to reset the values.
Note
The counters for the water treatment options can also be reset via security authori-
sation level 4
Extended configuration level
, see page 43.
8.11 Adjust dosing quantity
1. Switch to security authorisation level 1 user configuration level, see page 43.
2. Call up
i-menu
using the relevant confirmation key.
3. Select the
CHEMICAL PRODUCT
tab
4. Select and confirm the
Parameter
item.
5. Select and confirm the
Rinse aid dosing quantity
or
Detergent dosing quan-
tity
item.
6. Change the value with
+/-
and confirm.
8.12 Activate/deactivate Bluetooth interface
Note
The Bluetooth interface allows the service technician to read the machine's data
and is used for software updates. It is switched on as standard. If necessary, the in-
terface can be deactivated by the user.
1. Switch to security authorisation level 1
user configuration level
, see page
2. Call up i-menu using the relevant confirmation key.
3. Switch to the
global
tab.
4. Select the item
parameters
.
5. Confirm the selection.
6. Select the item
release Bluetooth communication
.
7. Confirm the selection.
Содержание 007DWUC1M2-10