Grounding Fault
WARNING:
Be
aware
that
only
qualified
personnel
should
troubleshoot
the
Micro
-
inverter
.
WARNING
:
DO NOT
disconnect the PV module from the Meikai Micro-inverter without
disconnecting AC power.
WARNING
:
Never
disconnect
the
DC
wire
connectors
under
load
.
Make
sure
that
no
current
is
flowing
in
the
DC
wires
prior
to
disconnecting
.
WARNING
:
N270
micro
-
inverter
is
powered
by
DC
power
,
when
you
reconnect
the
DC
wire
after
disconnect
make
sure
the
RED
LED
is
on
.
Trouble shooting Procedure
When PV module is operating normally and the power output is 40W or more,if the RED LED stays on,
indicates the micro-inverter is not operating correctly.
To troubleshoot an inoperable micro-inverter,please follow the steps in the order shown:
1. Check and verify the utility voltage and frequency are within allowable ranges shown in the
Technical Data section on page 16 of this manual.
2. Check the connection to the utility grid.disconnect the AC wire prior to didconnect DC
wires. Never disconnect the DC wires while the Micro-inverter is producing power.check if
the RED lED is on after reconnect the DC wires,check if the micro-inverter is attempting to
connect to the utility geid after reconnect the AC wires.
3. Check the connection between the micro-inverters in the AC branch, verify the utility grid
is operating normally.
4. Verify all the AC circuit breakers are functiong normally and closed.
5. Check the DC connection between the micro-inverters and the PV modules.
6. Verify the PV module DC voltage is within the allowable range shown in the Technical
Data section on page 16 of this manual.
7. Please call customer support at Meikai if the problem persists.
WARNING
:
DO NOT
attempt to repair the Meikai Micro-inverter, it is unrepairable. If it
fails, please return the unit to your distributor or Meikai Customer Service for
maintenance or replacement.
Disconnect the micro-inverter from the PV module
1. Disconnect the micro-inverter from the PV module follow the steps in the order shown
2. open the AC circuit breaker.
3. Disconnect the First connector in the AC branch
.