background image

26

INSTALLATION (CAMERA)

Installation

Camera can be installed on a tripod or a fixing
part from the upper plate or the bottom plate by
using the camera fixing holes (1/4", 20UNC) on
the tripod mounting base. The tripod mounting

base has been installed on the bottom plate

when shipped from factory.
Move the tripod mounting base when installing

the camera from the upper plate.

There are two camera fixing holes on the tripod
mounting base. Use the two holes to increase
the fixing intensity when installing the camera
specially.

Camera fixing holes

27

CONNECTIONS

Connect the video output of the camera to the video input of a monitor or other equipment. When using
a "loop through" connection of two or more monitors, set the 75

Ω

switch of only the final monitor to on.

Determine the type of cable according to the distance of the connected equipment.

Do not turn any component's power on until all connections are completed.

S-VIDEO

DC-Iris lens

To Lens connector

To Power input terminal

Power Source

(DC12V)

To Video input connector

Composite Video

S-Video

Содержание SI-C600N

Страница 1: ...tenance servicing instruc tions in the literature accompanying the appliance WARNING TO PREVENT THE RISK OF FIRE OR ELECTRIC SHOCK HAZARD DO NOT EXPOSE THIS CAMERA TO RAIN OR MOISTURE Due to design modification data given in this instruction book are subject to possible change without prior notice Information for USA This device complies with Part 15 of the FCC Rules Changes or modifications not a...

Страница 2: ...cabinet and the back or bottom are provided for ventilation and to insure reliable operation of the product and to protect it from overheating and these openings must not be blocked or covered The openings should never be blocked by plac ing the product on a bed sofa rug or other similar surface This product should not be placed in a built in installation such as a book case unless proper ventilat...

Страница 3: ...dirt with a dry soft cloth If it is extremely dirty use furniture cleaning tissue Do not use alcohols petroleum distillates liquid cleaners or sprays Daily check Make daily check for proper operation for surveil ance use In order to maintain normal operation the output of camera should be checked by user everyday for a clear and focused picture 5 FEATURES High sensitivity 1 2 412 000 pixels CCD wi...

Страница 4: ...ting base Mounting base for installing the camera 7 Power indicator Lights up when the camera is powered Video output connector BNC connector that outputs a composite video signal Setup buttons When use setting up and adjusting the camera with reference to the on screen menu See page 9 S VIDEO connector Output connector for separat ed Y C video signal Connect to the S VIDEO input connector of vide...

Страница 5: ...ccommodate usage conditions When connected to a monitor convenient on screen menus facilitate checking and changing the settings and adjustments A brief help lines is often presented on the screen below the list of commands The complete set of current parameters is saved and will be loaded each time turn on the camera until the next time change the setup The setting menus are illustrated on the ne...

Страница 6: ... to select the Lens mode 3 Position the cursor at AUTO and press the Set button to setting for Auto Iris Lens 4 Press the Left Right Up Down button to setting the Lens After setting position the cursor at RETURN and press the Set button to return to Setup Menu SETUP MENU LENS AUTO SHUTTER AGC AUTO WHITE BAL ATW BACKLIGHT OFF PICT ADJUST ATR OFF MOTION DET OFF NEXT EXIT SAVE ALL AUTO IRIS TYPE DC M...

Страница 7: ...adjusts the white balance SETUP MENU LENS AUTO SHUTTER AGC AUTO WHITE BAL ATW BACKLIGHT OFF PICT ADJUST ATR OFF MOTION DET OFF NEXT EXIT SAVE ALL ATW SPEED 239 DELAY CNT 016 ATW FRAME x2 00 ENVIROMENT INDOOR RETURN 12 SHUTTER AGC 1 Press the Set Button to display the Setup menu 2 Position the cursor at SHUTTER AGC and press the left or right button to select the Auto mode or Manual mode setting AU...

Страница 8: ...2 Position the cursor at PICT ADJUST and press the Set button to adjust the video output signal MIRROR Sets the horizontal flip for the display output BRIGHTNESS Sets the brightness of video output signal CONTRAST Sets the contrast of video output signal SHARPNESS Sets the sharpness of video output signal HUE Sets the HUE color of video output signal GAIN Sets the chroma gain of video output signa...

Страница 9: ...he screen 1 Position the cursor at Privacy and press the left right button to set Privacy ON 2 Press the Set button to enter the Privacy setup AREA SEL Selects the mask frame to be adjusted TOP Sets the top side of the mask frame BOTTOM Sets the bottom side of the mask frame LEFT Sets the left side of the mask frame RIGHT Sets the right side of the mask frame COLOR Sets the color of the mask frame...

Страница 10: ...ng Night operations BW BURST ON IR OPTIMIZER ON MODE AUTO LEVEL 015 RETURN 19 NOISE REDUCTION Noise reduction is a function that reduces the image noise in order to improve the image quality of the camera In particular it reduces the noise whichis generated under low brightness shooting conditions and other high gain states 1 Position the cursor at NR and press the Set button to setting the noise ...

Страница 11: ...The OSD menu displays support 7 languages English Japanese German French Russian Spanish and Portuguese Position the cursor at LANGUAGE and press the left right button to select a language The menus can be changed in real time in the selected language MENU CONFIGURATION CONFIDENTIAL OFF JOUR NUIT AUTO REDUCT BRUIT ID CAMERA OFF SYNC INT LANGUAGE FRANCAIS REINIT CAMERA BACK QUITTER SAVE ALL 21 CAME...

Страница 12: ...ctor When installing a video iris lens lens switch should be set to VIDEO position When installing a galvanometric iris lens lens switch should be set to DC position ADJUSTING AUTO IRIS LENSES Make this adjustment after connecting the camera to a power source and a monitor 1 Set AGC mode to off 2 When using a Video type lens Adjust the level control on the lens to pro duce minimum smear and optimu...

Страница 13: ...r use out doors or in very bright conditions When using a lens with an ND filter attached Shooting may not be possible with the mini mum required illumination specified 24 WITH A ZOOM LENS 1 Fully open the aperture and set the lens to the maximum tele photo position Then turn the focus ring to focus In the case of an auto iris lens only shoot a comparatively dark object so that aperture is fully o...

Страница 14: ...unting base Use the two holes to increase the fixing intensity when installing the camera specially Camera fixing holes 27 CONNECTIONS Connect the video output of the camera to the video input of a monitor or other equipment When using a loop through connection of two or more monitors set the 75Ω switch of only the final monitor to on Determine the type of cable according to the distance of the co...

Страница 15: ...00N NTSC SI C600P PAL Pickup element 1 2 Sony IT CCD Effective pixels SI C600N 768 H X494 V SI C600P 752 H X582 V Chip size 7 4 H X5 95 V mm Scanning system 2 1 interlace Scanning frequency SI C600N Hor 15 734kHz Ver 59 94Hz SI C600P Hor 15 625kHz Ver 50Hz Sync system Internal Video output Composite video signal 1Vp p 75Ω unbalanced Separated Y C signal Y 1Vp p 75Ω C 0 286Vp p 75Ω Hor Resolution 5...

Страница 16: ...30 MEMO ...