1.2 General Safety Guidelines 

 
 
Meiji Techno products are designed for safe operation under normal operating conditions. 
The instrument and accessories described in this manual have been built and tested 
according to industry safety standards for electronic laboratory instruments. Incorrect 
usage or non-conformance to operating instructions can cause personal injury or damage 
to equipment or property.  

 
1.3 Warning/Caution Symbols Used in this Manual 

 

You must be aware of all safety issues when you install and operate this microscope 
system. Several warning and caution symbols are listed below. These symbols are used 
throughout this instruction manual. For your safety, be sure to follow all instructions 
associated with the symbols listed below. 
 
 

   Possible electrical shock hazard exists 

 

    Disregarding instructions marked with this symbol may lead to serious 

injury or property damage. 

 
1.4 Intended Product Use 

 

Product Disclaimer:

 This product is designed and intended for use only as a stereo 

microscope fixturing system. Modifying this product in any way for use in any situation 
other than the original and intended product design will automatically void the warranty. 
In no event shall Meiji Techno be liable to any person for any incidental, indirect or 
consequential damages, arising out of or in connection with the use or performance of a 
modified or altered product.

 

 
1.5 Product Safety Information

 

        

 

 

 

     

 This microscope stand is not intended to be used in the immediate vicinity of 

water or a water outlet or placed in any location where water may penetrate the instrument. 
Water penetration may result in electrical shock or death. Choose only a suitable 
environment for your microscope stand. 
 
Do not subject any microscope system to extreme temperature fluctuations.  
Disassembly of the instrument may result in electrical shock, injury or death, equipment 
damage, loss of warranty coverage or may create other potential hazardous consequences.  
 

Содержание PKL

Страница 1: ...Model PKL Stereo Microscope Incident Transmitted Light LED Pole Stand Instruction Manual...

Страница 2: ...e Statement 1 5 Product Safety Information 1 6 Warranty Notes 2 0 The Stand and its Components 2 1 Set Up 3 0 Operation 3 1 Incident Light Operation Brightfield 3 2 Transmitted Light Operation Brightf...

Страница 3: ...matic voltage sensing power supply provides excellent specimen illumination and contrast The PKL is designed to meet your most diverse needs for stereo microscopy 1 1 Model PKL Features CAD Designed L...

Страница 4: ...roperty damage 1 4 Intended Product Use Product Disclaimer This product is designed and intended for use only as a stereo microscope fixturing system Modifying this product in any way for use in any s...

Страница 5: ...ion any instrument which under normal conditions of use and service proves to be defective in material or workmanship No charge will be made for labor or materials with respect to defects covered by t...

Страница 6: ...n return the product postage prepaid and insured to the authorized repair facility In most instances requests for warranty service will be performed in a prompt and routine manner and merchandise will...

Страница 7: ...2 0 The Stand and its Components The image below designates the main components of the PKL Stereo Microscope Stand...

Страница 8: ...ainer and remove the packing materials Save the container and packing in a dry location 2 Place the microscope stand on a stable work surface 3 Loosen the clamp screw on the PKL focus block and instal...

Страница 9: ...will void your warranty and could possibly lead to the stand no longer working 3 1 Incident Light Operation Brightfield 1 First set your interpupillary distance on the microscope eyetubes by pulling t...

Страница 10: ...tage and by using the focus knobs adjust your specimen into focus 4 0 Maintenance and Cleaning Disconnect the power cord on your equipment prior to performing cleaning maintenance or repair Keep elect...

Страница 11: ...lint free cotton cloth moistened with distilled water If that fails try using medical or reagent grade isopropyl alcohol 5 0 Troubleshooting Meiji Techno products are manufactured in Japan under ISO9...

Страница 12: ...stall the plastic fuse cover with the new fuse installed Re install the metal access cover plate NEVER USE REPLACEMENT FUSES OF A DIFFERENT RATING 6 0 Storage Protect your microscope from dust after e...

Страница 13: ...est authorized Meiji Techno Dealer in your area Call us toll free 800 832 0060 Monday through Friday 9am 5pm PST Miscellaneous Parts Optional Accessories MA667 Polarizing Plate Installs into the stage...

Страница 14: ...8 0 Physical Dimensions...

Страница 15: ...ttp www meijitechno com MEIJI TECHNO CO LTD 322 1 Chikumazawa Miyoshi machi Iruma gun Saitama 354 0043 Japan Phone Fax E mail Web 049 259 0111 049 259 0113 meiji meijitechno co jp http www meijit echn...