background image

Cleaning the Stage 

 
Use a soft brush or lint-free cotton cloth to removed dust and loose particles. 
 

DO NOT USE ACETONE OR OTHER HARSH CHEMICALS

, use a moistened lint-

free cotton cloth with a solution of mild soapy water. 
 

Cleaning of the Glass Stage Plate 

 
Use a soft brush or lint-free cotton cloth to removed dust and loose particles. 
 
For tough dirt, use a soft lint-free cotton cloth moistened with distilled water. 
 
If that fails, try using medical or reagent grade isopropyl alcohol. 

 
 

5.0 Troubleshooting

 

 
Meiji Techno products are manufactured in Japan under ISO9001 manufacturing 
standards. However, if you ever have any difficulty with any Meiji product, feel free to 
contact us at: 
 

Meiji Techno America 
2186 Bering Drive 
San Jose, CA 95131 
800.832.0060 
408.428.0472 FAX 

[email protected]

 

http://www.meijitechno.com

 

 
Our technical staff is trained to assist you on mechanical or electrical issues you may 
have.  
 
 

 
 
 
 
 
 
 
 

Содержание PKL

Страница 1: ...Model PKL Stereo Microscope Incident Transmitted Light LED Pole Stand Instruction Manual...

Страница 2: ...e Statement 1 5 Product Safety Information 1 6 Warranty Notes 2 0 The Stand and its Components 2 1 Set Up 3 0 Operation 3 1 Incident Light Operation Brightfield 3 2 Transmitted Light Operation Brightf...

Страница 3: ...matic voltage sensing power supply provides excellent specimen illumination and contrast The PKL is designed to meet your most diverse needs for stereo microscopy 1 1 Model PKL Features CAD Designed L...

Страница 4: ...roperty damage 1 4 Intended Product Use Product Disclaimer This product is designed and intended for use only as a stereo microscope fixturing system Modifying this product in any way for use in any s...

Страница 5: ...ion any instrument which under normal conditions of use and service proves to be defective in material or workmanship No charge will be made for labor or materials with respect to defects covered by t...

Страница 6: ...n return the product postage prepaid and insured to the authorized repair facility In most instances requests for warranty service will be performed in a prompt and routine manner and merchandise will...

Страница 7: ...2 0 The Stand and its Components The image below designates the main components of the PKL Stereo Microscope Stand...

Страница 8: ...ainer and remove the packing materials Save the container and packing in a dry location 2 Place the microscope stand on a stable work surface 3 Loosen the clamp screw on the PKL focus block and instal...

Страница 9: ...will void your warranty and could possibly lead to the stand no longer working 3 1 Incident Light Operation Brightfield 1 First set your interpupillary distance on the microscope eyetubes by pulling t...

Страница 10: ...tage and by using the focus knobs adjust your specimen into focus 4 0 Maintenance and Cleaning Disconnect the power cord on your equipment prior to performing cleaning maintenance or repair Keep elect...

Страница 11: ...lint free cotton cloth moistened with distilled water If that fails try using medical or reagent grade isopropyl alcohol 5 0 Troubleshooting Meiji Techno products are manufactured in Japan under ISO9...

Страница 12: ...stall the plastic fuse cover with the new fuse installed Re install the metal access cover plate NEVER USE REPLACEMENT FUSES OF A DIFFERENT RATING 6 0 Storage Protect your microscope from dust after e...

Страница 13: ...est authorized Meiji Techno Dealer in your area Call us toll free 800 832 0060 Monday through Friday 9am 5pm PST Miscellaneous Parts Optional Accessories MA667 Polarizing Plate Installs into the stage...

Страница 14: ...8 0 Physical Dimensions...

Страница 15: ...ttp www meijitechno com MEIJI TECHNO CO LTD 322 1 Chikumazawa Miyoshi machi Iruma gun Saitama 354 0043 Japan Phone Fax E mail Web 049 259 0111 049 259 0113 meiji meijitechno co jp http www meijit echn...

Отзывы: