MeiG Smart product technical information
SLM500
Hardware Design Guide
Page 63
current
GSM Standby power consumption
-
-
4.0
mA
WCDMA Standby power
consumption
-
-
3.9
mA
TD-S Standby power consumption
-
-
4.0
mA
CDMA Standby power consumption
-
-
3.8
mA
FDD Standby power consumption
4.45
mA
TDD Standby power consumption
3.5
mA
Call
Current
consumpt
ion
GSM900 CH62 32dBm
-
-
250
mA
WCDMA2100 CH10700 22.5 dBm
-
-
550
mA
Digital
transmissi
on
GPRS GSM900 CH62 PCL5 1DL
4UL
-
-
TBD
mA
EGPRS GSM900 CH62 PCL8 1DL
4UL
-
-
TBD
mA
Imax
Peak
current
Power control at maximum output
power
-
-
3
A
6.9 Electrostatic Protection
The module is not specifically protected against electrostatic discharge. Therefore, users
must pay attention to electrostatic protection when producing, assembling, and operating
modules.
6.10 Module Operating Frequency Band
The table below lists the operating frequency bands of the module and complies with the
3GPP TS 05.05 technical specification.
Table 6.9: Module Operating Band
Frequency band
Receive
Transmission
Physical channel
GSM850
869
~
894MHz
824
~
849MHz
128~251
EGSM900
925
~
960MHz
880
~
915MHz
0~124
,
975~1023
DCS1800
1805
~
1880MHz
1710
~
1785MHz
512~885
WCDMA B1
2110
~
2170 MHz
1920
~
1980 MHz
TX: 9612~9888
RX: 10562~10838
WCDMA B5
869
~
894MHz
824
~
849MHz
TX: 4132~4233
RX: 4357~4458
WCDMA B8
880
~
915MHz
925
~
960MHz
TX: 2712~2863
RX: 2937~3088
CDMA BC0
869
~
894MHz
824
~
849MHz
1
~
799
;
991
~
1023
TDSCDMA 1.9G
1880
~
1920 MHz
1880
~
1920MHz
9400
~
9600
TDSCDMA 2G
2010
~
2025 MHz
2010
~
2025MHz
10054
~
10121