4
2564 2565 2566 2567 2568 2569 2570 2571
Step 7 time
2588 2589 2590 2591 2592 2593 2594 2595
2596 2597 2598 2599 2600 2601 2602 2603
Step 8 time
2620 2621 2622 2623 2624 2625 2626 2627
2628 2629 2630 2631 2632 2633 2634 2635
Repeat start step
2652 2653 2654 2655 2656 2657 2658 2659
2660 2661 2662 2663 2664 2665 2666 2667
Repeat end step
2684 2685 2686 2687 2688 2689 2690 2691
2692 2693 2694 2695 2696 2697 2698 2699
Repeat count
2716 2717 2718 2719 2720 2721 2722 2723
2724 2725 2726 2727 2728 2729 2730 2731
The value alarm 1
2748 2749 2750 2751 2752 2753 2754 2755
2756 2757 2758 2759 2760 2761 2762 2763
The value alarm 2
2780 2781 2782 2783 2784 2785 2786 2787
2788 2789 2790 2791 2792 2793 2794 2795
The value alarm 3
2812 2813 2814 2815 2816 2817 2818 2819
2820 2821 2822 2823 2824 2825 2826 2827
The value alarm 4
2844 2845 2846 2847 2848 2849 2850 2851
2852 2853 2854 2855 2856 2857 2858 2859
Overlap/Deadband
3036 3037 3038 3039 3040 3041 3042 3043
3044 3045 3046 3047 3048 3049 3050 3051
Undershoot suppresion
factor
3068 3069 3070 3071 3072 3073 3074 3075
3076 3077 3078 3079 3080 3081 3082 3083
Heat side proportional
band adjusting factor
3164 3165 3166 3167 3168 3169 3170 3171
3172 3173 3174 3175 3176 3177 3178 3179
Heat side integral
band adjusting factor
3196 3197 3198 3199 3200 3201 3202 3203
3204 3205 3206 3207 3208 3209 3210 3211
Heat side derivative
band adjusting factor
3228 3229 3230 3231 3232 3233 3234 3235
3236 3237 3238 3239 3240 3241 3242 3243
Analog output
4262 4263 4264 4265 4266 4267 4268 4269
4270 4271 4272 4273 4274 4275 4276 4277
Heating side control
output (MV)
1532 1533 1534 1535 1536 1537 1538 1539
1540 1541 1542 1543 1544 1545 1546 1547
Temperature rise speed
3356 3357 3358 3359 3360 3361 3362 3363
3364 3365 3366 3367 3368 3369 3370 3371
Temperature drop speed
3388 3389 3390 3391 3392 3393 3394 3395
3396 3397 3398 3399 3400 3401 3402 3403
Control object
character
3420 3421 3422 3423 3424 3425 3426 3427
3428 3429 3430 3431 3432 3433 3434 3435
PID arithmetic
3452 3453 3454 3455 3456 3457 3458 3459
3460 3461 3462 3463 3464 3465 3466 3467
PID output upper limit
3484 3485 3486 3487 3488 3489 3490 3491
3492 3493 3494 3495 3496 3497 3498 3499
PID output lower limit
3516 3517 3518 3519 3520 3521 3522 3523
3524 3525 3526 3527 3528 3529 3530 3531
PID output dead band
3548 3549 3550 3551 3552 3553 3554 3555
3556 3557 3558 3559 3560 3561 3562 3563
Hand/ automatic smooth
transfer
3580 3581 3582 3583 3584 3585 3586 3587
3588 3589 3590 3591 3592 3593 3594 3595
Error status word
(system error)
3612
Error status word
(broken even error)
3613
Set value range error
address
3616
3617
Channel
characteristics
confirmation command
3624
3625
Control start / stop
settings
3628
3629
3630
3631
Self-tuning setting
value
3636
3637
reset
3640
Change settings
allowed
3644
CH1-CH16 multi-stage
control execution flag
3648
3649
Alarm 1 mode setting
3652
Alarm 2 mode setting
3656
Alarm 3 mode setting
3660
Alarm 4 mode setting
3664
Alarm dead zone
setting
3668
Alarm delay times
3672
External input status
3680
3681
Cold junction
temperature
3620
Module parameter
saving
3684
Module software
version information
3688
Thermostat
identification code
3692
PID parameter hidden
switch
4582
System error status word
(
3612
)
Bit status
ON(1)
OFF(0)
Bit0:Error
When any error of b1 ~ b7 occurs,
this flag bit is 1 (any one of b1 ~
b2 is 1, all channels AD conversion
stops)
No error
Bit1:Remain
-
-
Bit2:Hardware
malfunction
AD converter or other hardware
failure
Normal
Bit3:Setting value
backup error
When there is an error due to
interference and MTCW internal, the
flag bit changes to 1. Please
contact the sales agent or our
company if the error cannot be
cleared after the power is cut off
and reconnected
Data
backup is
normal
Bit4:Cold junction
temperature
compensation error
Bit5:Remain
-
-
Bit6:Set value
recovery is error
This flag bit is 1 if there is an
error reading the backup data due to
interference and internal errors in
MTCW
-
Bit7~Bit15:Remain
-
-
Broken even error status word
(
3613
)
Bit status
ON(1)
OFF(0)
Bit0 ~ Bit15 broken
couple detection
(only supports
thermocouple)
When thermocouples of channels 1 to
16 are broken
This flag
is 1
channel
without
broken
even
error
Ethernet function
:
Name
Address 1
Address 2
Address 3
Address 4
Protocol
selection
4180
Native
gateway
4181
4182
4183
4184
Native mask
4185
4186
4187
4188
Native IP
4189
4190
4191
4192
Local port
4193
Remote IP
4194
4195
4196
4197
Remote port
4198
Protocol selection
(
4180
)
Function
TCP server
TCP client
UDP
MODBUS
16#0001
16#0002
16#0003
MODBUS_TCP
16#0101
16#0102
16#0103
7. CT input
7.1 Functional specifications
1.There are two kinds of measured currents, which are set according
to "CT action".
①
general current measurement (clamp table mode) occasions.