Chapter
III
Dex CM3000 13
Full-Digital Control CO2/MAG/MIG Multi-FunctionWelding Machine
Arc Starting Time
(
F29
)
1.
Long press "Function" key more than 3 seconds to enter into internal menu, turn the left knob to F29.
2.
Turn the right knob to adjust parameters under F29 (shown in table 3-18).
3.
Short press "Function" key to exit internal menu, F29 parameter settings is completed.
Table 3-18 Parameters of Arc starting
Function Code
Unit
Adjusting Range
Step Length
Default Value
F29
0
~
10 Seconds
0.1
0
DC Welding EnergyControl
(
F55
)
1.
Enter into internal menu by long pressing “Function” key; turn the panel knob to F55.
2.
Adjust F55parameters by rotating the right knob (table 3-19)
3.
Press “Function” key again to exit from internal menu, F55parameter settings is completed.
Table3- 7Parameter Table of DC Power Control
Function Code
Unit
Adjusting Range
Step Length
Default Value
F55
/
0~200
1
0
Logic diagram of manual welding parameters.
As shown in the figure3-6.
Arc Striking
Current
Arcing Process
Thrust Current
Short Circuit
Welding Process
Current
Voltage
No-Load Voltage
Welding Machine Power-
On
Contact Workpiece
Hot-Start Time
The End of Welding
Fig.3- 4 Manual Welding Logic Diagram
MMA Arc StartingCurrent
(
F52
)
1.
Enter into internal menu by long pressing “Function” key; turn the panel knob to F52.
2.
Adjust F52parameters by rotating the right knob (table 3-20)
3.
Press “Function” key again to exit from internal menu, F52 parameter settings is completed.
Table3- 20Parameter Table of MMA ArcInitiationCurrent
Function Code
Unit
Adjusting Range
Step Length
Default Value
F52
A
0~400A
1A
300A
MMA Hot-Starting Current
(
F53
)
1.
Enter into internal menu by long pressing “Function” key; turn the panel knob to F53.
2.
Adjust F53parameters by rotating the right knob (table 3-21)
3.
Press “Function” key again to exit from internal menu, F53 parameter settings is completed.
Step