91398 Rev A.1 01/16
Page 7 of 8
Run speed
Can be set manually using the up and down arrows.
Sensor mV/g
Accelerometer sensitivity (mV/g) can be manually set using the up and down arrows from
1 - 1000 mV/g. This enables the resolution and range of the meter to be set by the user.
2.3.3 Device settings
There are two pages of Device settings options. Use the arrow buttons to scroll through the options, and the
POWER button to select.
Auto Off Time
Can be set from 1 minute up to a maximum value of 60 minutes, in increments of 1 minute.
Brightness
Can be set between 1 (least brightness) up to 10 (full brightness).
Language
The operating language can be selected depending on model.
Graph mode
Displays the frequency spectrum as either a line graph or a bar graph.
Color scheme
The display can be configured as standard (full color) or monochrome for convenient viewing in direct
sunlight.
Time and Date
Time and date can be set using the arrow buttons.
Units
Sets velocity readings to be displayed in mm/s or inch/s.
Run speed units
Sets run speed unit to Hertz (Hz), revolutions per minute (RPM) or cycles per minute (CPM).
3.0 Asset management
Press the Asset Manager button to access the Machines menu.
Machines have user-defined names up to 16 characters long. Scroll through the list with
the up and down arrows. Select a machine with the circle button to bring up a list of
measurement points for that machine.
Measurement points also have user-defined names up to 16 characters long. Scroll
through the list of measurement points with the up and down arrows and select with the
circle button.
Options for each measurement point (MP):
•
Take Reading
– takes a new reading and saves it to this MP
•
Save Reading
– saves the previously taken reading to this MP