Continuity Measurement [
Ω
]
Range switch set to [
Ω
] range
Test Lead options 1 or 2
The MFT1500 will automatically display continuity resistance
when connected.
Lead Null
Short test leads together and press the YELLOW test button on
the instrument or Switched Probe.
Continuity Buzzer (
Z
)
The buzzer will sound automatically when a circuit is made
(default threshold <2
Ω
)
Buzzer Threshold (
Z
)
Select BUZZER range and press the ORANGE button until
required range is displayed.
Options, 2
Ω
, 5
Ω
, 10
Ω
, 20
Ω
, 50
Ω
, and 100
Ω
Warning:
Ensure the circuit to be tested is disconnected and
isolated before starting testing.
Voltage, Continuity and Insulation testing
Voltage measurement (V)
Range switch set to (V) range
The MFT1500 will automatically display circuit voltage up to
500 V a.c./d.c.
Backlight (MFT1502 only)
Intelligent mode - operates automatically. To switch to manual
mode, press the RED lock and the BLACK backlight buttons
together.
OPTION 2
Switched
probe
OPTION 1
2 wire lead
set
BLACK
BLACK (BACKLIGHT)
YELLOW (TEST)
RED
(LOCK)
BLUE (0º - 180º) ORANGE (BUZZER)
BLACK
RED
PROBE