![MegaSquirt 2Extra Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/megasquirt/2extra/2extra_parallel-installation-manual_1765205016.webp)
The picture below shows the placement on the V3.0 board of the 4 injector channels. The standard injector drivers
components can be left on the board but will be unused and will not interfere with injector channels 1 and 2. The
injectors channels 3 and 4 connect to pads originally used for the MS1 clock circuit and require the removal of those
components for proper and safe operation. The injector channel 3 shows 2 pads because they correspond to the same
electrical location (use either one). The components to remove are: R21,C20,C21,R22,R23,Y1,C24,C25