Troubleshooting
Problem:
The Thermostat will not consistently operate remotely.
Solution:
The Remote/Thermostat/Lightwave Link may be encountering
interference or may be at the edge of its reliable range of operation. First,
ensure that there are no large pieces of metal or bodies of water in the path
of the transmission. If the problem persists, try moving the Controller/Link
closer to the Socket.
Problem:
TRVs / Electric Switches / ‘unlink’ themselves from the Thermo-
stat after linking other devices to it.
Solution:
There is a limited number of devices that the Thermostat and other
LightwaveRF heating devices can link to. If this is exceeded, previous devices
will lose their connections. Note also that if linking several devices of the same
type, they must be ‘daisy chained’ together (see previous instructions).