background image

5

 

Main Power Connection

 

Important Information!

 

 

1.  Deco Lighting fixtures are specifically designed to be used with a Deco Drivers.

 

2.

 

 Maximum Cable distance of 100ft before voltage drop. (voltage drop will cause intensity drop)

 

3.

 

 Max Power 20W output driver 

1

 unit per output

 

4.

 

 Max Power 96W output driver 

5

 units per output

 

5.

 

All fixtures connected together must be same type (do not connect Variable White or Single                

Color fixtures in the same output)

 

6.

 

 Must use 22 AWG cable or thicker to connect the fixture and fixture to fixture. 

 

The occupation of the connection

-

cable is as follows:

 

DMX

-

512 Control

 

COM

 

V

 

Black Cable

 

R

 

Red 

 

Red Cable

 

G

 

Green

 

Green Cable

 

B

 

Blue

 

Blue Cable

 

W

 

Warm White

 

White Cable

 

When using the Deco Cove Q18 with Deco Drivers the fixture is intended to be used in Ch4 or Ch7 modes.  The Deco 

Driver will be required to be set in Ch4 or Ch7 operating modes

 

Ch7 Mode

 

Dimmer

 

Red

 

Green

 

Blue

 

Warm White

 

Strobe

 

Macro

 

Ch4 Mode

 

Red 

 

Green

 

Blue

 

Warm White

 

5

 

Deco Driver Info

 

 

  

  

Power Link

 

20W Output Driver                            

 

Can connect 

unit per output port

 

  

96W Output Driver

 

Can connect 

5

 unit per output port

 

Ch Mode

 

Ch 4 or Ch7

 

Use  Ch4 or Ch7 Mode to control the unit

 

Содержание DECO Cove Q18

Страница 1: ...of Contents Safety Information 3 What Is Included 3 Specifications 4 Main Power Connection 5 DMX 512 Control 5 Deco Driver Info 5 Size Weight 6 Cleaning Maintenance 7 Rigging the Fixture 7 Warranty 8...

Страница 2: ......

Страница 3: ...be left on for long periods of time Protection Against Electrical Fire 1 Disconnect power before servicing 2 For connection to main power supply proceed to page 5 3 This fixture must not be left on f...

Страница 4: ...sing FR 4 Aluminum PCB Lens Angle 120 Housing Curving Limited Curving of 160 degree Connection Female Pin Head 2 0 5P Size 40 inch 101 6 cm long Cuttable Cuttable every 3 92 inch 99 7mm LED Spacing 63...

Страница 5: ...to connect the fixture and fixture to fixture The occupation of the connection cable is as follows DMX 512 Control COM Voltage Black Cable R Red Red Cable G Green Green Cable B Blue Blue Cable W Warm...

Страница 6: ...6 Size Weight Fixture Size 40 1016mm X 59 15mm X 27 7mm Fixture Packaged 41 X 2 X 5 Net Weight 1lb Gross Weight 15lb 59 15mm 3 93 100mm Whole Size 12 3 2mm 64 16 4mm 40 1016mm 27 7mm...

Страница 7: ...stallation must be carried out by an authorized dealer or trained professional 2 Unit may cause severe injures if you have doubts concerning the safety do not install 3 Unit is to be 24inches away fro...

Страница 8: ...8...

Страница 9: ...swer any question should you encounter a prob lem Please visit our website for any other related technical documents For service related issue please contact our service dept Monday Friday 9am to 6pm...

Отзывы: