MegaLife ML-PC10AO-K5NNA1A Скачать руководство пользователя страница 17

13

Drain Water

2. Screw the drain connector to(included in the

package) the spout by turning clockwise.

3.

ATTENTION:

Insert the drainage hose into drain connector.

When using continuous drainage option from the middle

hole, place portable on a level surface and make sure 

garden hose is clear of any obstructions and is directed 

downward. Placing portable on an uneven surface or 

improper hose installation may result in water filling up 

the chassis and causing the unit to shut off. Empty water

in the chassis if shut off occurs, then check portable lo-

cation and hose for proper setup.        

Содержание ML-PC10AO-K5NNA1A

Страница 1: ...nstructions Portable air conditioner Model ML PC10AO K5NNA1A ML PH12AO K5NNA1A ML PC12AO K5NNA1A Thank you for choosing our product Please read this Owner s Manual carefully before operation and retai...

Страница 2: ...ction for Icons on Display Screen 1 Installation in sash window Optional 1 2 6 8 10 11 12 Function Introduction for Combination Buttons Replacement of Batteries in Remote Controller Maintenance 7 7 12...

Страница 3: ...bol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information used to indicate r...

Страница 4: ...example open flames an operating gas app liance or an operating electric heater The appliance shall be stored in a well ventilated area where the room size corresponds to the room area as specified f...

Страница 5: ...hen contact local dealer When nobody is taking care of the unit please turn it off and remove the power plug or disconnect power Prohibit operating the unit in the bathroom or laundry room Far away fr...

Страница 6: ...essionals to deal with it Do not use an extension cord Please put the air conditioner at smooth and flat ground for operation to avoid noise and vibration This air conditioner is equipped with castors...

Страница 7: ...OPER 7 Sleep Timer 8 Health WiFi 10 9 Remote controller Some installation accessories can t be discarded On Off Fan Mode Swing 1 Controller panel Guide louver NOTICE 4 5 6 Filter Air inlet Middle drai...

Страница 8: ...ir conditioner will give out a sound Meanwhile corresponding indicator on control panel will be bright Under OFF status dual 8 nixie tube on control panel won t display Under ON status dual 8 nixie tu...

Страница 9: ...sion of the signal Do not leave the remote control in direct sunlight or ne ar a heater Protect the remote control from moisture and shock Set time TIMER ON TIMER OFF Light Up down swing Child lock Se...

Страница 10: ...imer button Health button This function is not applicable for this model Under ON status press this button to set timer OFF Under OFF status press this button to set timer ON Press this button once an...

Страница 11: ...ons Temperature display switchover function Under OFF status press and Mode buttons simultaneously to switch temperature display betw een C and F using the remote controller Replace new batteries of t...

Страница 12: ...on the air conditioner Eliminate accumulated water in chassis refer to the section of Drainage way for details Check whether window bracket is damaged or not If yes please contact dealer dition Check...

Страница 13: ...he unit again Whether the unit is interfered by thunder radio etc 1 Pour out the water inside chassis 2 If H8 still exits please contact profess ional person to maintain the unit If the malfunction st...

Страница 14: ...c safety regulations when Other places with special circumstances It s not allowed to be installed on the unstable or motive base structure such as truck or in the corrosive environment such as chemic...

Страница 15: ...ews FAN Fan Swing Mode OPER Sleep On Off Timer Health WiFi Optional 1 Mothproof net Bracket Screw Mounting plate Fixed clip Fixed base Sponge B Sponge A Optional 3 Optional 2 Optional 4 Drainage hose...

Страница 16: ...age port to drain water After draining insert the rubber plug Press ON OFF button to restart To reach the maximum performance it is not recommended to drain water during Cool mode It is recommended to...

Страница 17: ...option from the middle hole place portable on a level surface and make sure garden hose is clear of any obstructions and is directed downward Placing portable on an uneven surface or improper hose in...

Страница 18: ...0 465 25 25 25 25 25 25 25 465 127 255 128 128 123 123 Window panel Adjustment panel Extension panel Exhaust cover Fixed base Fixed base Fixed base Fixed base Window panel Adjustment panel Fixed clip...

Страница 19: ...ion of window and screw down by a Mounting plate C 1 2 3 4 5 6 7 Assemble the window kit as below 5 For windows with inner width or height of 770mm push two fixed bases to the end of Window Panel A Fo...

Страница 20: ...Window panel Stuff the Foam seal A between the glass and the window to prevent air and insects from getting into the room 2 Attach the window panel to the window stool Make sure that the exhaust cove...

Страница 21: ...haust cover is attached to the window panel 770mm 1210mm 770mm 1650mm 1210mm 5 Attach the bracket with a screw Recommend ed Bracket Sliding sash window Optional 1 1 Please lay a tabular material under...

Страница 22: ...below figure by the manufacturer Note of Installing heat discharge pipe User can adjust the installation method of the discharge pipe basing on the requirement while the similar installation methods...

Страница 23: ...4 3 Install the other side of heat discharge pipe clock wise into joint D Joint D Insert joint A of heat discharge pipe into the gro ove until you hear a sound Groove joint A Insert joint A of heat di...

Страница 24: ...nd remove the Rear clip by pushing down two PUSH markings slide and close the exhaust cover in the window panel Optional Joint Joint H 1 2 Remove joint F remove joint F from joint H Disassembly for in...

Страница 25: ...RD C1 SA M2 YEGN M1 YEGN PE PE RD CAP CAP BN ROOM TEMP BN RD SENSOR RT1 TUBE TEMP SENSOR OUTTUBE TEMP SENSOR RT3 VALVE 4 WAY 4YV WATER MOTOR YEGN RECEIVER BOARD POWER L N BN BK BU WH YEGN GN N2 WATER...

Страница 26: ...22 b a Specialist s Manual 4 2 Aptitude requirement for maintenance man repairs should be done only be specialists Safety preparation work 2...

Страница 27: ...be avoided as the chlorine may react with the refrigerant and corrode the copper pipe work If a leak is suspected all naked flames shall be rem oved extinguished If a leakage of refrigerant is found w...

Страница 28: ...and that ventilation is available Specialist s Manual Decommissioning a Become familiar with the equipment and its ope ration Isolate system electrically Before attempting the procedure ensure that b...

Страница 29: ...ng the equipment that is at hand and shall be suitable for the recovery of all the relevant waste transfer note arranged Do not mix refrigerants in recovery units and especially not in cylinders If co...

Страница 30: ...66129937317...

Отзывы: