![MegaHome MH943S Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/megahome/mh943s/mh943s_instruction-manual_1764819019.webp)
Distiller Body Trouble Shooting
Problems
1.Body heating problem
2.The RESET button does
not work
3.Too much water
remains in the distiller
after a distillation
process
4.Burnt sockets
6.Water leakage from
the body
7.Collected distilled
water less than 4 liter
5.Burnt main power cord
Causes
(1)No power supply to the body,
power cords and sockets have
connection problem.
(2)Blown fuse(It sometimes
happens in the middle of the
distillation process.)
(3)Main Power cord malfunction
(4)Thermal switch was not fully
engaged.
(1)Thermal switch malfunction
(2)The spring in the RESET button
is jammed
(1)Thermal switch malfunction
(2)Blown fuse(It sometimes
happens in the middle of the
distillation process.)
(3)Structure of stainless steel tank
is malfunctioned.
Check 2 sides of power cords and
sockets having any bad connection
problem or not.
Check the function of wall outlet is
normal or not.
Check the function of RESET button
is normal or not.
Replace fuse
Replace the main power cord
Press the RESET button again
Replace the Thermal switch
Re-check and reinstall the spring in
the RESET button
Replace the thermal switch
Check and replace the fuse
Check and replace the new Distiller
body.
The power cords were not properly
plugged in that results in a poor
connection and it’s melted
Replace sockets
Power cord is deformed due to
improper operation
(1)The stainless steel tank is broken
(1)Poured less than 4 liter of water
(2)The fan stops running that
causes to lose the steam
(2)Water drips from Top to the
bottom
Replace main power cord
Replace the stainless steel tank
Check the Top during the distillation
Pour the water till the“FULL”line
Check the function of fan and power
is normal or not
Solutions
18