CAUTION
Water discharged may be very hot!
●
Manually operate the temperature/pressure relief valve for a few seconds.
●
Check water is discharged and that it flows freely through the tundish and
discharge
pipework.
●
Check valve reseats correctly when released.
●
Repeat the above
procedure for the expansion relief valve.
Strainer
●
Turn off the isolating valve prior to the Pressure Reducing Valve or the main
stop cock to
the system.
●
Open the lowest hot tap in the system to relieve the system
pressure.
housing. The strainer will be removed with the cartridge.
●
Wash any
particulate matter from the strainer under clean running water.
●
Replace the
strainer and screw the Pressure Reducing Valve cartridge into the moulded
housing.
●
Close hot tap, turn on isolating valve or main stop cock to the
system. Check for leaks.
Descaling immersion heater(s)
●
Turn off the mains water supply, isolate the electrical supply and turn off
boiler
●
Attach a hosepipe to the drain cock having sufficient length to take
water to a suitable
discharge point below the level of the unit.
●
Open a hot tap close to the unit
and open drain cock to drain unit.
●
Open the cover(s) to the immersion heater
housing(s) and disconnect wiring from
immersion heater(s) thermostat(s).
●
Remove the 8 nuts and withdraw the
immersion heater. Take care when lifting the
immersion heater out of the cylinder and work within safe working practices.
●
Carefully remove any scale from the surface of the element(s).