COUNTER CHARACTERISTICS

Protection from dust/water, IP 60

The device is intended to be installed inside where water cannot reach it. The sensor is 
inside a dust-proof casing with IP 60 protection:

6  

– No ingress of dust; complete protection against contact

– No protection against water

Dimensions

People counter: 

42х68х18 mm

Data-collecting ETH-modem: 66x66x28 mm

Data export, server

OMEGA CLOUD
FTP
SFTP (SSH File Transfer Protocol)
HTTP
HTTPS

Data export, protocol

OMEGA
XML
JSON
TXT

Modem interface

ETH through operating systems WINDOWS, LINUX, iOS

Power supply

АА 1.5 V batteries: 2 per each counter block
Battery change is carried out by the user
Power consumption 60 

µA

Delivery kit

People counters - 2 blocks, R-T
ETH-modem - 1 pc
Adhesive pads - 4 pcs
L-brackets - 2 pcs
Screws - 4 pcs
USB cable - 1 pc
АА 1.5 V batteries - 4 pcs
ETH power supply - 1 pc
Patch-cord - 1 pc

Operating time on a single battery set

Up to 1 year on one set of batteries, depending on device settings

Distance between the modem and the counters. Radio channel

Counters can be up to 200m away from the modem, depending on radio broadcast
and obstacles

8

Содержание OMEGA-ETH

Страница 1: ...megacount io PEOPLE COUNTER User Manual OMEGA ETH...

Страница 2: ...MEGACOUNT Ltd Disclaimer MEGACOUNT Ltd ensures that the contents of this document are accurate and complete but is not legally responsible for the information provided The user is fully responsible fo...

Страница 3: ...ING BATTERIES WRONG POLARITY CAN LEAD TO COUNTERS BREAKING AND BATTERIES OVERHEATING TO AVOID DAMAGE THAT CAN CAUSE A FIRE OR ELECTROCUTION KEEP THE DEVICE AWAY FROM WATER RAIN AND HIGH HUMIDITY IT IS...

Страница 4: ...UNTERS 12 STEP 3 CONNECTING THE COUNTER TO THE ETH MODEM 14 STEP 4 SETTING THE DISTANCE BETWEEN THE COUNTERS 15 STEP 5 MOUNTING THE COUNTERS TO THE SUFRFACE 16 STEP 6 COUNTER CONFIGURATION 17 STEP 7 D...

Страница 5: ...atteries 4 1 5 V batteries 2 per each counter block Adhesive pads type 1 2 Pads for mounting the counter on a surface Adhesive pads type 2 2 Pads for mounting the counter on a surface Screws 4 Screws...

Страница 6: ...t each other they create two beams between them Each time the beams are crossed block R detects the fact of crossing and its direction stores that data and later transfers it to the Ethernet modem as...

Страница 7: ...ETH modem see the manual Infrared band 990 nm Dimensions 42 mm height 68 mm length 18 mm width Direction indicator Bi directional counting BLUE RED Unidirectional counting BLUE RED Photovoltaic cells...

Страница 8: ...protocol OMEGA XML JSON TXT Modem interface ETH through operating systems WINDOWS LINUX iOS Power supply 1 5 V batteries 2 per each counter block Battery change is carried out by the user Power consum...

Страница 9: ...password use the password changing option in Settings Administration Double click to open settings window Change to necessary settings 9 DEFAULT SETTINGS IP 192 168 1 218 MASK 255 255 255 0 GATEWAY 19...

Страница 10: ...F THE MODEM THE TIME IS SET FROM SNTP TIME SERVERS IF THE NETWORK IS CLOSED SET UP A SEPARATE TIME SERVER AND PUT ITS DETAILS IN THE SETTINGS TIME ZONE IS TO BE CHOSEN CORRECTLY TIME IS TO BE SET IF T...

Страница 11: ...rotective black screen Opening the casing Installing batteries in blocks R and T Install batteries into holders with correct polarity as shown on the picture below POLARITY MUST BE FOLLOWED CORRECTLY...

Страница 12: ...R block for connection to the ETH modem Open the counter casing and press the button Service while the program is scanning as shown on the picture below Press the button at the moment when the program...

Страница 13: ...needed for the T block Connecting additional counters and adding them to OMEGA ETH program If there are additional pairs of counters follow the same connection process as described before for the R bl...

Страница 14: ...sary to configure the T block by setting the correct distance between the blocks Open the casing of the T block and set the distance on it by moving the correct switch to the right as shown on the pic...

Страница 15: ...cture below Main recommendation when mounting counters blocks fix the counters so that the R block is facing the ETH modem When mounting the counters mind the door handles they should not be in the co...

Страница 16: ...ltaneously no need to additionally divide end values by two Entrance indicator If the indicator is red when someone enters put in RED if the indicator is blue when someone enters put in BLUE Important...

Страница 17: ...t OMEGA CLOUD connecting the counter to cloud analytics with the possibility to view data via any browser and smartphone HTTP S packet data transfer in JSON or XML format to a server that supports TLS...

Страница 18: ...ND A REQUEST TO info megacount io When you are connected to the analytics program it will be possible to view data with a browser on any PC laptop or smartphone Name Any name ID for the data export e...

Страница 19: ...ACCEPTED TEXT MESSAGE ONLY THEN WILL THE PROGRAM SEND THE NEXT DATA PACKET HTTP S settings Name Any name ID for the data export e g Analytics My data export etc Protocol http or https with TLS encrypt...

Страница 20: ...wing end value one day many files File name Compound file name format ID and CD tags are obligatory Port Port address of the server to which the data will be pushed URI Receiving script resource ID Se...

Страница 21: ...tor The counter confuses In and Out directions at a large distance It is recommended to switch the counter to the unilateral counting mode choose unilateral counting mode in the counter settings wait...

Страница 22: ...at have accepted the recycling system This marking implies prohibition of disposing of the equipment together with other household waste Device contains batteries If disposed of incorrectly batteries...

Страница 23: ...as intended indoors under normal conditions Service life 7 years Warranty 1 year MEGACOUNT MANUFACTURER MEGACOUNT LTD 73472165005 134 Mendeleeva St UFA 450022 Russia info megacount io megacount io EAC...