STEP 6.
COUNTER CONFIGURATION
To configure the counter, double-click on the name of the counter or choose [Counter
configuration] in the context menu
[Name]
Counter ID
– for example, Left entrance, Main entrance, Right entrance, etc.
[Counting mode]
Bi-directional
– sensor counts for both In and Out and the indicator lights
up with blue or red depending on the direction. Unidirectional
– sensor counts only in one
direction and logically divides the data by two, both indicators blink simultaneously; no
need to additionally divide end values by two
[Entrance indicator]
If the indicator is red when someone enters
– put in RED, if the
indicator is blue when someone enters
– put in BLUE. Important!
[Data transmission]
Optimal interval is every 5-8 hours. The bigger the interval, the more
battery is saved
[Operating time]
The counter is set up to work around the clock by default. It is necessary
to set up proper operating time and exclude non-operating days and time
Operating time of the counter and the [Data transmission] parameter directly affect
battery life. Set up correct operating and non-operating days and time and a
reasonable data transfer interval. Important!!!
16