![Mega MEg 30 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/mega/meg-30/meg-30_manual_1764026012.webp)
4.10 Reference ambient conditions
Ambient temperature:
20°C ± 2°C
Relative humidity:
40% to 60%
Air pressure:
86 kPa to 105 kPa
Without hoarfrost, bedewing, rain and sunshine
4.11 Ambient conditions
Operating temperature:
–20°C to +60°C
Operation:
in indoor space
Relative humidity:
20% to 90%
Altitude:
up to 2000 m
Operating position:
arbitrary
Protection:
IP40
Category of measurement:
IV (ČSN EN 61010-1)
Degree of contamination:
2
Protection under condition of one failure is ensured by protective impedance
with a combination of component parts.
4.12 Supply
Supply from any measuring input U1, U2, U3
Range of input power:
5 VA
Back-up supply:
battery SANYO N-50AAA L 1×5,
in average during up to five
intervals of 1 minute at reference
ambient conditions
Replacement of the battery shall be carried out by the manufacturer basing on
order.
Mean time between battery replacements makes 2 years.
4.13 External connection
Terminals S1, S2 of signal SYNC
U0:
0 V to 5 V DC and AC
U1:
20 V to 200 V DC and AC
The terminals are galvanicly separated by an optoelectronic element with
insulation strength 5 kV