Mega FP?8000 XL Скачать руководство пользователя страница 5

3.4

 

Run

 

photoplotter

 

 

Before

 

you

 

start

 

plotting,

 

make

 

sure

 

that

 

drum

 

is

 

in

 

its

 

initial

 

position

 

(white

 

arrow

 

on

 

the

 

left

 

side

 

of

 

the

 

drum

 

should

 

be

 

aligned

 

with

 

white

 

arrow

 

on

 

the

 

top

 

of

 

the

 

left

 

holder

 

of

 

the

 

drum).

 

After

 

you

 

prepared

 

your

 

data

 

for

 

plotting

 

on

 

connected

 

PC

 

using

 

photoplotter

 

software,

 

start

 

plotting

 

see

 

further

 

info

.

 

The

 

photoplotter

 

drum

 

starts

 

slowly

 

to

 

rotate.

 

After

 

drum

 

reaches

 

its

 

working

 

speed,

 

it

 

rotates

 

a

 

while

 

before

 

actual

 

plotting

 

starts.

 

At

 

this

 

moment

 

red

 

(or

 

yellow)

 

LED

 

labelled

 

Laser

 

starts

 

to

 

light

 

as

 

an

 

indicator

 

that

 

plotting

 

is

 

in

 

progress.

 

When

 

photo

plotting

 

is

 

finished

 

or

 

interrupted

 

by

 

STOP

 

command,

 

drum

 

automatically

 

stops,

 

laser

 

head

 

moves

 

back

 

to

 

its

 

outgoing

 

position

 

and

 

LED

 

labelled

 

Laser

 

stops

 

light.

 

Time

 

needed

 

for

 

photo

plotting

 

of

 

given

 

image

 

is

 

displayed

 

on

 

computer

 

in

 

dialog

 

window

 

of

 

control

 

software

.

 

 

 

Do

 

not

 

start

 

plotting

 

again

 

before

 

the

 

laser

 

light

 

head

 

reaches

 

completely

 

its

 

initial

 

position

 

(the

 

left

 

side

 

of

 

the

 

screw)!

  

 

Note

:

 

Because

 

various

 

films

 

used

 

for

 

photo

plotting

 

are

 

differently

 

sensitive

 

to

 

light,

 

it

 

is

 

possible

 

to

 

adjust

 

intensity

 

of

 

laser

 

light

 

as

 

needed

 

in

 

photoplotter

 

software,

 

also

 

in

 

respect

 

to

 

selected

 

resolution.

 

This

 

setting

 

may

 

also

 

be

 

needed

 

to

 

adjust

 

time

 

after

 

time

 

to

 

reflect

 

the

 

status

 

of

 

chemicals

 

used

 

for

 

film

 

wet

 

processing.

  

Open

 

the

 

lid

 

(dark

 

green

 

light!!!)

 

and

 

remove

 

film.

 

Process

 

film

 

immediately.

  

Note:

 

After

 

removing

 

film

 

from

 

drum

 

surface,

 

it

 

may

 

be

 

necessary

 

to

 

clean

 

the

 

drum

 

surface

 

to

 

remove

 

sticky

 

areas

 

caused

 

by

 

sticky

 

tape.

 

Use

 

soft

 

cloth

 

and

 

common

 

liquid

 

cleaner.

 

Do

 

not

 

spray.

 

Drum

 

surface

 

under

 

film

 

must

 

be

 

kept

 

clean

 

and

 

dry

.

  

 

ATTENTION!

 

During

 

photo

plotting

 

is

 

film

 

(drum)

 

lighted

 

by

 

laser

 

light

 

that

 

is

 

harmful

 

to

 

human

 

eye.

 

Do

 

not

 

open

 

photoplotter

 

lid

 

during

 

photo

plotting,

 

nor

 

during

 

testing

 

without

 

film

 

 

4.

 

PHOTOPLOTTER

 

SOFTWARE

 

 

 

4.1

 

Brief

 

Description

 

 

 

Photoplotter

 

software

 

comes

 

on

 

one

 

CD

 

together

 

with

 

ViewMate

 

program

 

for

 

viewing

 

Gerber

 

files

 

and

 

with

 

a

 

brief

 

manual

 

in

 

PDF

 

format.

 

It

 

must

 

be

 

installed

 

on

 

PC

 

under

 

with

 

Windows

 

98

 

or

 

higher.

  

CD

 

contains

 

5

 

directories

 

 

Install,

 

Manual,

 

Update,

 

Util,

 

Viewmate

  

 

Install

 

directory

 

contains

 

photoplotter

 

control

 

software.

 

This

 

program

 

can

 

be

 

installed

 

on

 

computer

 

by

 

executing

 

its

 

own

 

installation

 

program

 

SETUP.EXE

.

 

Installation

 

creates

 

a

 

new

 

directory

 

(default

 

FP

8000

 

under

 

Program

 

Files

)

 

with

 

two

 

programs

 

(

Gerb2bitmap

 

and

 

Run_Photo_USB

.

  

 

Gerb2bitmap.exe

 

reads

 

in

 

Gerber

 

files.

 

It

 

allows

 

to

 

view

 

Gerber

 

data

 

as

 

they

 

appear

 

on

 

the

 

film,

 

edit

 

D

codes,

 

do

 

film

 

penalization,

 

and

 

converts

 

Gerber

 

file

 

into

 

photoplotter

 

bitmap

 

file

 

(.FPF),

 

which

 

can

 

be

 

read

 

into

 

plotter

 

control

 

program

 

(Run_photo_USB)

 

to

 

be

 

used

 

for

 

photo

plotting.

 

It

 

can

 

also

 

convert

 

various

 

formats

 

of

 

aperture

 

files

 

into

 

Lavenir‘s

 

format,

 

which

 

is

 

used

 

by

 

this

 

plotter.

  

 

Run_photo_USB.exe

 

controls

 

photo

plotting.

 

Reads

 

in

 

bitmap

 

files

 

like

 

photoplotter

 

FPF,

 

regular

 

BMP

 

and

 

controls

 

plotting

 

process.

 

It

 

allows

 

to

 

set

 

output

 

resolution

 

as

 

well

 

as

 

to

 

calibrate

 

photoplotter

 

in

 

X

 

and

 

Y

 

coordinates.

  

 

Latest

 

photoplotter

 

software

 

is

 

located

 

in

 

Update

 

directory.

 

Please,

 

copy

 

the

 

files

 

into

 

photoplotter

 

directory

 

(default

 

FP

8000

 

under

 

Program

 

Files

).

  

 

Manual

 

directory

 

contains

 

this

 

manual

 

and

 

Adobe

 

Acrobat

 

Reader

 

program.

  

 

Util

 

directory

 

contains

 

program

 

MM2INCH.EXE

 

(mm

 

to

 

mils

 

converter).

  

 

 
 

 

Содержание FP?8000 XL

Страница 1: ...hotoplotter is driven by program Run_photo_USB which reads in hi resolution bitmap files FPF photoplotter proprietary file format and BMP From this reason if you work with Gerber or Postscript files these files must be converted into one of these bitmap files format first Gerber files are converted by program Gerb2bitmap which is a part of the photoplotter software while Postscript files are conve...

Страница 2: ...tioning on film glue unglue image location automatic positioning of associated images on different layers Photoplotter software is supplied on CD with installation program Requires Pentium computer with at least Windows 2000 and USB port 100 MB HD space minimum for software and output files The computer speed has influence on plotting time Plotting files may be quite large in range of tens of MB s...

Страница 3: ... software go to directory Install on installation CD supplied with the photoplotter and execute SETUP exe Software starts to install on connected computer 3 2 Power the photoplotter Connect supplied power supply unit with the photoplotter connector is located on the back side Switch power on left side of the photoplotter The green LED labelled Power will come on Red or yellow LED labelled Laser wi...

Страница 4: ...he left top corner of photo plotted area is then approximately 20 mm from the left edge of the drum on the horizontal line marked by white arrow Place film on the drum with its top edge approximately 20 mm behind the white mark on the drum hold it firm by hand and fix it to the drum by means of a masking tape along the top edge Rotate drum by one hand to be able to fix film s bottom edge but make ...

Страница 5: ...d common liquid cleaner Do not spray Drum surface under film must be kept clean and dry ATTENTION During photo plotting is film drum lighted by laser light that is harmful to human eye Do not open photoplotter lid during photo plotting nor during testing without film 4 PHOTOPLOTTER SOFTWARE 4 1 Brief Description Photoplotter software comes on one CD together with ViewMate program for viewing Gerbe...

Страница 6: ... associated drill It also has a built in converter of aperture files made in various CAD software Eagle Pads OrCad Protel P CAD etc The large grey area on the screen represents plotting area of the photoplotter The top left corner of grey field area has 0 0 plotting coordinates with increasing Y coordinate going vertically down and increasing X coordinate running horizontally to the right The coor...

Страница 7: ...ing Master Gerber and Associated Gerber makes sense only in case of several artworks like Top side routing Bottom side routing Silkscreen Soldermask etc from the same board will be photo plotted while one of them Master will be panelised the other ones Associated must be then be panelised too and be positioned exactly to the same location as the Master image If films are not panelised than every G...

Страница 8: ...tically fill all needed information in it The user can verify the source of aperture file by clicking on Guess Format the converter will report the name of the program where aperture file was created The conversion will start by clicking on Start or F4 Exit converter by using ESC keyboard button When converter closes confirm OK on a small dialog window The name of loaded aperture file will be disp...

Страница 9: ...ociated with this one on selected layer Use Job Preview or an icon to preview result of Gerber to bitmap conversion for selected layer It is possible to make holes openings in otherwise filled pads to make manual drilling easy specify Hole Size in Pads As some pads for example SMD do not have any holes specify D codes without holes for these pads Similarly to view created technological area define...

Страница 10: ...Use Job 500 dpi Bitmap to generate BMP file named Clip bmp for checking purpose you can display it in any bmp viewer if nothing more than Paint Brush in Windows will do that ...

Страница 11: ...ed with the Master file soldermask etc on selected layer film Job Import Apertures loads aperture file for selected layer film Job Exit ends the program EDIT Edit Insert Mark allows to insert a small Gerber image to the film see Preference Mark Edit Copy to Clipboard Edit Delete Board or an icon deletes selected board image s and associated Gerber and aperture file Edit Lock All Boards glues image...

Страница 12: ......

Страница 13: ...llows to convert selected aperture file PREFERENCE Preference Memory Setting allows to specify computer memory size used for calculations Recommended size RAM memory 20MB The more memory available the faster calculation of bitmap Preference Plotting Area Size allows operator to set max Size of displayed plotting area Preference Data Format allows operator to set format of loaded Gerber file Prefer...

Страница 14: ...Preference Tech Area allows to set parameters for so called robber strip copper strip around board outline used for board manufacturing purposes An example of Tech Area the robber strip ...

Страница 15: ...r F3 command allows to read in input file generated previously in Gerb2bitmap program FPF format or Windows BMP format see picture on the next page FPF file can be previewed before loading and its image size resolution and user notes created in Gerb2Bitmap is displayed Please note that image size is extended by 10mm on each side In case of BMP file its image cannot be viewed here Its resolution MU...

Страница 16: ...to program by OK button Loading may take some time depending on file size If loaded file size is smaller than 14 MB than its image is displayed otherwise a message File is too big to display but plotting will be OK is displayed ...

Страница 17: ...e look right but keep in mind that this image is here displayed only for your information When image is displayed use Tools Run photoplotter or button A new dialog box appears where it is possible to set plot output resolution reversed Negative and mirrored Mirror plotting Time needed for plotting is shown automatically Click on Plot will start the plotter The higher output resolution the longer p...

Страница 18: ...ting conditions at the user site temperature humidity film Angle Error represents a linear inaccuracy between the right angle plot and the real non right angle plot on a line 360 mm long along drum axis This is one half of vertical distance between corresponding horizontal lines of the two films measured 360 mm from the left 0 position while one of the films is flipped upside down Screw Error repr...

Страница 19: ...rum axis direction may be entered into setup table for related distance Plot size depends on values written in files Drum axis and Drum circumference The grid lines are plotted with thickness specified in field Line width If Include setup table is checked then setup table will be automatically included at the bottom of the plot If serial number of the photoplotter is written in field S N then this...

Страница 20: ...Continue as with any other plot file use Run photoplotter Tools Run Photoplotter or button ...

Страница 21: ...tensity automatically increases with every next image by value entered in filed Increment Number of images is set by value in field Number Click on button OK starts plot Light Allows to pre set values for intensity of laser light related to used film sensitivity and output resolution For films with higher light sensitivity the values are lower Values go also down for higher resolution regardless o...

Страница 22: ...sity of laser light Light if needed otherwise this value is pre set in dialog window under Light command Time needed for given file and set resolution is also indicated Plotting time Note that for the higher resolution the longer time is needed Click on Plot button to start photo plotting It takes a while for plotter drum to reach needed speed to rotate before it starts to plot The remaining plott...

Страница 23: ... layer s in Active Layer Corresponding images will be automatically placed in the same location on the film as the Master Gerber image When Master image is moved or panelised all related images are also moved or panelised If Master image is deleted all related images files are also deleted 5 2c Load aperture file s for associated Gerber images Make sure that aperture files are loaded on the same l...

Страница 24: ...Do not start plotting again unless laser head has returned to its initial position 6 How to make test films Occasionally it is needed to make test films just to find out proper working conditions like light intensity or plot accuracy To make test film to find out proper light intensity Use strip of film approx 100 mm wide and 300 mm long and tape it to the drum longer side over drum Use command To...

Страница 25: ...ference direction enter measured differences in Drum Linearity table for every particular grid where error appears d If there are errors only in certain areas along the drum axis screw direction enter measured differences in Screw Linearity table for every particular grid where error appears e If lines drawn horizontally in drum axis direction are not perpendicular to lines in vertical direction d...

Страница 26: ...MAIN SWITCH POWER 24V 2 5A DC DRUM MOTOR SCREW MOTOR LASER PANEL LED SCREW MICROSWITCH LASER LASER HEAD PHOTOPLOTTER 8000 DPI PCB TERMINALS CABLE BLOCK DIAGRAM FP8000 FP8000XL Photoplotter Insts 0611 ...

Страница 27: ... VIEW WITH LID OPEN Auto Manual Switch Power Laser Main Switch Mega Electronics Ltd Mega House Grip Industrial Estate Linton Cambridge United Kingdom CB21 4XN Telephone 44 0 1223 893900 Fax 44 0 1223 893894 Email sales megauk com web www megauk com ...

Отзывы: