Cleaning and maintenance
Installation Maintenance:
The operator has to make sure that the unit is operating safely and has the installa-
tions and electronics checked by an expert every 2 years.
The following points have to be considered during the inspection:
1) All screws used for installing the device or part of the device have to be tightly connected and must not be corroded.
2) There must not be any deformations on the housing, fixation and installation spots (ceiling, suspension, trussing).
3) Mechanically moved parts like axles and other must not show any traces of wearing and must not rotate with unbal-
ances.
4) The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any
safety problems have to be removed.
Disconnect from mains before starting maintenance operation!
Caution Danger to life!
We recommend a frequent cleaning of the device. Please use a moist, lint free cloth. Never use alcohol or solvents!
1) The objective lens will require periodic cleaning on usage and environment. Environment with foggers will require
more periodic cleaning as fog fluid tends to build up residues, reducing the light output.
2) The cooling-fans should be cleaned monthly. DO NOT blow high pressure air into fans as incorrect rotation can
damage the fans operation.
3) The lenses may be cleaned with soft brush using soapy water.
4) The interior of the fixture should be cleaned using a vacuum.
5) We recommend proper lubrication of the motor wheel. The quantity of the oil must not be excessive in order to avoid
oil run outs when motor wheel rotates
Note:
There is no serviceable parts inside the device except for the fuse. Maintenance and service operations
are to be carried out by authorized dealers.
Replacing the fuse:
Only replace the fuse with the same type and rating.
Replacing the power cable:
If the power cable of this device becomes damaged, it has to be replaced by author-
ized dealers only
Should you have further questions , please contact your dealer.
13
Parts List
1125-LEDMOD
LED Module
1125-PS
Power Supply
1125-DR
LED Driver
1125-MPCB
Main PCB/ Display Card
P-1125
4 Axis QD7 Case
1125-CM
Clamp Mount
1125-PTS
Pan & Tilt Sensor
1125-FAN
Fan 60mm
1125-ARMB
Arm Body Set
1125-DISB
Display Body Set
1125-HEADB
Head Body Set
1125-HANB
Handle Set