background image

 

MEFE—Mitchell Engineering Food Equipment Pty Ltd 
23 Storie Street Clontarf QLD 4019 Australia 
www.mefe.com.au | [email protected] 

Page 4 

+617 3283 4536 

Free AU 1800 669 006 

Battery Install and Operation 

1. 

Install 2 x AAA batteries. For first use or if changing the batteries, please wait about 10 minutes for the apparatus to 
warm up before turning on by pulling the measurement trigger. Secure the battery cover using the screw supplied. 

2. 

If the device has not been used for a long time, when you turn it on again it will automatically measure the room tem-
perature first and delay turning on for 1—2 seconds. If leaving the device for a long time, remove the batteries.  

3. 

Select the body mode, aim towards the chosen surface (usually forehead) keeping 2—5 cm sensing range, and pull the 
measuring trigger once. The temperature will display accompanied by a single beep.  

4. 

If the measurement temperature is 38.0°C or higher indicating a fever, the device should emit 6 rapid beep sounds to 
alert the user. The backlit display will be red. 

NOTE: 

If you have manually adjusted your default alarm threshold for 

alerting a fever, this will only occur at your new setting. Please refer to the Setting function F2. 

5. 

To turn off the device, simply do not touch it. It will automatically turn off after 15 seconds. 

 

Setting Functions and Operation

 

CAUTION: 

We recommend you leave the default settings. To restore to  

Factory Default 

hold down MODE for 7 seconds.  

 

Mode  Function 

Operation Step 

F1 

Set °C / °F 

Press MODE button for 2 seconds, the screen will display F1 on the bottom 
right. Press (+) UP or (-) DOWN button to change the temperature unit. 

F2 

Set alarm temperature 

Press MODE button for 2 seconds, the screen will display F1, press MODE again 
to get to F2. Select (+) UP to increase the threshold by 0.1°C (0.1°F). The alarm 
threshold default value is 38°C (100.4°F). 

F3 

Set difference 

Press MODE button for 2 seconds, press again twice to cycle through to F3. Se-
lect (+) UP  to increase the difference by 0.1°C (0.1°F) or (-) DOWN to reduce it 
by 0.1°C/F. In the case of seasonal or environmental change, please verify and 
adjust according to the operation instructions in this manual.  

F4 

Set buzzer on/off 

Press MODE button for 2 seconds, press again three times to cycle through to 
F4. Select (+) UP to turn on the buzzer, press (-) DOWN to turn it off. 

 

Measurement mode 

There are 2 measurement modes for this device.  

Body (forehead) mode: 

Range = 32.0—43.0°C (86.0-109.4°F) 

Surface (object) mode: 

Range = 0—100°C (32.0-212.0°F) 

 

3 colours backlight 

In body mode, the device will display a different colour depending on the read-
ing. 

Green

 (Normal) = 32.0—37.4°C (86.0—99.3°F) 

Orange 

(Slight Fever) = 37.5—37.9°C (99.5-100.2°F) 

Red 

(Fever) = 38.0-43.0°C (100.4-109.4°F) 

In surface mode, the backlight will always display green. 

 

Data memory 

The device will automatically store body data memory after temperature meas-
urements, with up to 99 readings stored. To display the last reading or cycle 
through data memory, press the (+) UP or (-) DOWN buttons. 

The device cannot save readings on surface mode. 

Отзывы: