Filter replacement

1

3mm Allen Key

Screws

x 2

Anti

Clockwise 

to loosen

2

3

W

ater Flow

Check the water 

flow direction on 

the 

new filter

a

b

Push fit the 
correct pipes 
into the filter

4

Once the new filter is installed

Connect the unit to a pressurized water 
source and check for any leaks.

* If a leak is found turn off the water 
supply and check connections.

Disconnect water supply

Disconnect or turn off the water supply. 
De-pressure the unit by pushing the buttons

.

First Flush

The first flush of water from the unit will be 

Black 

in colour.

This is normal and will disappear after a 
few seconds of water flow from the unit.

Reset Flow meter after filter change

* See flow meter instructions

Press 

down

 on 

the locking ring

a

b

Pull 

up

 on the 

pipe to remove

* Some models will not 

have a bracket

*Once a panel has been removed.

Locate the filter inside the unit

I look like this

3mm Allen Key

Screws

x 2

Clockwise 

to tighten

5

Содержание MP-TO-01

Страница 1: ...ownsend Street Albury NSW 2640 Australia Phone 02 60217813 61260217813 Email sales meetpat com au Meet PAT Meet PAT Limited NZ meetpat co nz 12 Bethlehem Road Bethlehem Tauranga 3100 THE one permanent...

Страница 2: ...not use if any leaks are prevalent Units can be heavy to install use the appropriate number of people and equipment Ensure the units are regularly cleaned and serviced If applicable ensure the water...

Страница 3: ...hin the units The units are mounted to a 8mm powder coated steel bollard Graphics panels are made from clear high impact spray paint uv and scratch resistant polycarbonate sheet The graphics are back...

Страница 4: ...kpa operating pressure Filter 5 micron carbon filter Flow Rate 5L per minute pressure dependent Power None Flow Meter Digital in litres Minimum Working Temp 1 C Water Supply Connection 1 2 inch supply...

Страница 5: ...many different positioning options These options can allow you to install a unit very cost effectively with minimal infrastructure changes Water supply The unit can be connected to any existing potabl...

Страница 6: ...te slab using the mounting bracket Units can bolt directly onto existing ooring structure Connect through to existing connections on the other side of walls Connect waste water into existing drainage...

Страница 7: ...5mm Attaching to an existing structure Embedding in concrete Installation Kit Not included Base plate sizing Unit can be xed to any ooring structure Meetpat recommends 4 x M12 Countersunk Stainless St...

Страница 8: ...luded Length and type of the fastener to be con rmed by installer Unit can be embedded into a new concrete slab Meetpat recommends a minimum slab size of 550W x 550L x 200mmD This may need to be incre...

Страница 9: ...m slab size of 550W x 550L x 200mmD This may need to be increased or reinforced depending on sub surface conditions Con rm with installer for suitable slab site Please contact Meetpat for a installati...

Страница 10: ...pat com au Meet PAT Meet PAT Limited NZ meetpat co nz 12 Bethlehem Road Bethlehem Tauranga 3100 Panel replacement 3mm Allen Key Screws x 3 Clockwise to loosen 1 2 3 3mm Allen Key Screws x 4 Clockwise...

Страница 11: ...ed NZ meetpat co nz 12 Bethlehem Road Bethlehem Tauranga 3100 Panel replacement 8mm Allen Key Screws x 1 Anti Clockwise to loosen 7 8 9 Putting it back together All nished and need to put the unit bac...

Страница 12: ...unit to a pressurized water source and check for any leaks If a leak is found turn off the water supply and check connections Disconnect water supply Disconnect or turn off the water supply De pressu...

Страница 13: ...y the total liter count up 3000lt Attention 1 Do not spray water into or around the ow meter 2 Be careful to not damage the wires when removing the ow meter 3 For replacement parts and troubleshooting...

Страница 14: ...ff bracket 2 4mm Allen Key Screws x 4 Anti Clockwise to loosen Only portable models will have a bracket 4 x 2 1 I look like this Record ow meter data If still displayed record the ow meter data Once t...

Страница 15: ...to change without notice This technical sheet is copyright and owned by Meet PAT Products and Things Pty Ltd as a trustee for Meet Pat Unit Trust ABN 42634465637 All rights are reserved All products...

Отзывы: