Alarm (only on Hyperion 907 Power Unit)
This is the level of performance (Ion Level) at which the Clean Pin Alert will be
triggered. Typically set at 60% it can be set higher for more critical applications.
Ion Level (only on Hyperion 907 Power Unit)
This is an instantaneous measure of the performance of the bar, compared to its
performance when new and clean. A low percentage could indicate that the bar needs
cleaning.
Reset Ion Ref.
This function is used to set reference performance level when the bar is clean. It is set
by Meech during initial calibration. It should be reset after making changes to either
the balance or the frequency of the output.
Make sure that the bar is clean before resetting the Ion Ref Current.
Disconnecting Bar Master
Warning:
It is recommended to turn-off the 24V power supply to the BarMaster and
wait a few seconds before disconnecting the power cable from the power unit. Failure
to do so will not damage the equipment, but may result in a small shock caused by the
stored energy in the power unit.
Reconnect the 24V supply cable to the power unit and turn the power supply on. The
power unit will operate at the new settings.