Using the 994IML
The 994IML can be used very simply with local control of the voltage and monitored
using the front panel LEDs. For more sophisticated installations, the output voltage can
be controlled via a 0-5 Volt analogue input. Remote monitoring of the output voltage
and current is also provided by 0-5V analogue outputs. The state of the HT output is
reported via a 5V signal.
In-built protection circuitry will prevent the output from exceeding 500mA, by limiting the
output voltage. When the protection is in operation the front panel LED will illuminate
and the 5V output signal will activate.