background image

8

Output / Input Signals

The 8 Way Mini DIN connector offers the following connections:

Function

2 Metre Cable

5 Metre Extension Cable

Terminal 1

Ground (0V)

Black

Orange

Terminal 2

Voltage control 

0-5V = 0-20kV

Brown

Red

Terminal 3

Output voltage setting

0-5V = 0-20kV

Red

Yellow

Terminal 4

Remote ON/OFF. OFF 

when grounded (lo)

Orange

Purple

Terminal 5

Remote voltage control 

enabled when 

grounded (lo)

Yellow

Brown

Terminal 6

Output current

0-5V = 0-500µA

Green

Green

Terminal 7

5V if unit is overloaded

Blue

Blue

Terminal 8

5V when HT on

Purple

Black

Diagram

Male Plug

Item Code

A900-DATA-CAB-2M

A900-DATA-CAB-5M

Drawing

F

M

M

Typical wiring of mini DIN cable for Remote on/off and HT voltage control.

1

2

3

4

5

6

7

8

0V

0-5V Input. HT voltage control

Remote on/off open=on

Remote voltage control enable

5

6

7

8

4

2

1

3

1

2

3

4

5

6

7

8

Содержание 994IML

Страница 1: ...MODEL 994IML Static Generator Operating Manual...

Страница 2: ......

Страница 3: ...t Input Signals 8 Using the 994IML 9 Specification 10 CE Approval 10 Maintenance 11 Repairs And Warranty 11 994IML Static Generator Case and Mounting Detail 12 Products shown in this document may be c...

Страница 4: ......

Страница 5: ...ator has been designed to work with the Hydra In Mould Label pinning system It provides 0 20kV Negative polarity in a lightweight package powered by 24V DC Full local and remote control makes it ideal...

Страница 6: ...or packing material and immediately notify the carrier of a possible damage claim Shipping claims must be made by the consignee to the delivering carrier In addition please also notify Meech Internati...

Страница 7: ...l 1 Power LED 2 HT On LED 3 Overload LED 4 Rotary Voltage Control Side Panel 1 Ground post 2 On Off Switch 3 24V DC Inlet Centre Positive 4 8 Way Mini DIN Control interface 5 Remote On Off 6 HT Output...

Страница 8: ...ed either by using the ground post or by using a grounded 24V supply or both 994IML 220V AC 24V DC 0V Power Supply Grounded 0V Grounding using ground post Mounting Mount the unit using the 5mm keyhole...

Страница 9: ...HT output using the proprietary grey HT connector Ensure the plug is securely fastened using the locking collar If only one HT output is used the unused output should be blanked off with the plug prov...

Страница 10: ...ded lo Orange Purple Terminal 5 Remote voltage control enabled when grounded lo Yellow Brown Terminal 6 Output current 0 5V 0 500 A Green Green Terminal 7 5V if unit is overloaded Blue Blue Terminal 8...

Страница 11: ...led via a 0 5 Volt analogue input Remote monitoring of the output voltage and current is also provided by 0 5V analogue outputs The state of the HT output is reported via a 5V signal In built protecti...

Страница 12: ...Supply 24V DC 750 mA Max Output Voltage 0 20kV Negative Max Output Current 500 microAmps CE Approval An EC declaration of conformity for this product exists in respect of the Low Voltage Directive 72...

Страница 13: ...your local distributor All products returned to the factory MUST be accompanied by a return authorisation number and must be shipped prepaid For prompt service ship the unit to the factory with the r...

Страница 14: ...12 994IML Static Generator Case and Mounting Detail...

Страница 15: ......

Страница 16: ...Tel 1 330 564 2000 1 800 232 4210 Fax 1 330 564 2005 email info meech com Meech Shavotech 29 2 Kharadi Off Pune Nagar Road On Old Kharadi Mundhwa Road Pune 411014 Maharashtra India Tel 91 0 703 093 82...

Отзывы: