Issue 2
Page 7
7/12/01
233v3
Pulsed DC Controller
Tests must be completed by a qualified electrical engineer.
If in doubt contact Meech head office or your local distributor.
CAUTION:
While no danger to personnel exists, it is essential than any high
voltage ionizing equipment, (exception Meech Model 910 Water Resistant Ionizing
Bars), makes no contact with water or water based fluids.
Should such an event occur, disconnect immediately and return equipment to the
manufacturer for water damage assessment. High voltage electrical equipment
should not make contact with water.
The Model 233v3 Power Supply and attached ionizing products form part of a
system. To verify where a fault may have occurred it is important to test each item
of the system individually. Should more than one ionizing appliance be connected
to the power supply, these must be tested individually.
To check the Pulse DC system follow the procedure detailed below:
1)
Switch off the electrical supply to the system.
2)
Disconnect all ionizing appliances from the controller.
3)
Reconnect the supply and switch ON the unit.
4)
Using a high voltage probe ( 1000:1 ) and meter measure the voltage on
each of the output sockets. The reading should be at Max. power 8 kV
5)
If the controller is found to be functional test each of the attached products
independently following the instructions detailed in the appropriate Opera-
tion and Maintenance manual.
If the 233v3 controller is found to be faulty please contact your local distributor or
Meech Meech Static Eliminators 330-564-2000 (800-232-4210).
FAULT FINDING