Section 5:  Service Instructions – Gas Spring 

Replacement MedViron 46” Overbed Table  

 

This manual is intended for trained professionals for adjustment of the MedViron Overbed Table.  Any 
action not outlined in this manual may result in voiding of the warranty. 

Before moving to this step, first attempt the adjustment in Section 1.

   

The overbed table contains a single locking gas spring for height adjustment.  This gas spring keeps 
the table from being lowered until the handle is activated, but allows free rise.  Gas springs can lose 
force over time, which will cause the table to descend faster when activated.  

Tools required 

 

#2 & #3 Phillips Screwdriver (Powered driver not recommended except where noted) 

 

7/16” socket or wrench  

 

 

 

Block (provided) 

 

5.0

 

Replacing the gas spring 

 

5.1

 

Lift table to the highest adjustment position.  Remove shelf or drawer pedestal following 

instructions in Section 6. 

Содержание OBT 46

Страница 1: ...Service Manual 46 Medviron Overbed Table...

Страница 2: ...ontents Section 1 Cable Tension Adjustment Section 2 Caster Replacement Section 3 Plug Replacement Section 4 Top Replacement Section 5 Gas Spring Replacement Section 6 Pedestal Service Section 7 Vanit...

Страница 3: ...tting This may fix the gas spring Tools required 2 Phillips screwdriver OBT Wrench provided 1 0 Table drifts down without application of the handle 1 1 This adjustment requires a 2 Phillips screwdrive...

Страница 4: ...wrench 2 0 Turn the over bed table upside down To replace casters that are worn or malfunctioning first raise the unit to its fullest extension Turn the over bed table upside down and place on a prote...

Страница 5: ...er bed table upside down or on its side To replace damaged or worn end plugs first raise the unit to its fullest extension Turn the over bed table upside down or on its side and place on a protected s...

Страница 6: ...owered driver not recommended 4 0 Remove the top Raise the unit to its fullest extension Remove drawer tubs or shelves pedestal cover plate and handle sleeve do not need to be removed for top replacem...

Страница 7: ...ble contains a single locking gas spring for height adjustment This gas spring keeps the table from being lowered until the handle is activated but allows free rise Gas springs can lose force over tim...

Страница 8: ...gas spring lever Figure 1 5 4 Remove the top plate by first loosening 4 screws Figure 1 A power driver may be required for this operation Figure 1 Figure 2 5 5 Remove the top washer by removing the 2...

Страница 9: ...ing using the clevis pin Figure 4 5 9 Insert the gas spring into the column and attach the bottom washer to the column with the two screws removed in step 5 7 5 10 Attach the X Base to the column usin...

Страница 10: ...pring is not activated Secure the lock nut 5 14 Attach the top as shown in Section 4 Make sure the pins for the hanging pedestal are in the plate 5 15 Attach the hanging pedestal and shelves as descri...

Страница 11: ...pedestal from the unit Raise the unit to its fullest extension If only replacing drawers or shelves remove as illustrated in the User Manual and replace with new part s If replacing sides or rods move...

Страница 12: ...s from the old side by removing the 4 screws in the slide and attach the slide to the new side with the screws DO NOT OVERTIGHTEN If new drawer slides were ordered attach the new slides to the new sid...

Страница 13: ...e stop is too tight a slotted screw driver may be used to lightly pry the stop Figure 1 The vanity can be replaced the same way it was removed Figure 1 7 2 Replacing the vanitytray If replacing the va...

Страница 14: ...3 screws on the same rail If the vanity is too tight use the same process but move the rail slightly farther away from the vanity Figure 2...

Отзывы: