– 2 –
Warranty Disclaimer – United States
Note: Although the PTFE Coated Guide Wire, hereafter referred to as “product”,
has been manufactured under carefully controlled conditions, Medtronic, Inc., and
affiliates (collectively, “Medtronic”) have no control over conditions under which this
product is used. Medtronic therefore disclaims all warranties, both expressed and
implied, with respect to the product including, but not limited to, any implied warranty
or merchantability or fitness for a particular purpose, shall not be liable to any person
or entity for any medical expenses or any direct, incidental or consequential damages
caused by any use, defect, failure or malfunction of the product, whether a claim for
such damages is based upon warranty, contract, tort or otherwise. No person has any
authority to bind Medtronic to any representation or warranty with respect to the
product.
The exclusions and limitations set out above are not intended to and should not be
construed so as to contravene mandatory provisions of applicable law. If any part or
term of this Disclaimer of Warranty is held to be illegal, unenforceable or in conflict
with applicable law by a court of competent jurisdiction, the validity of the remaining
portions of this Disclaimer of Warranty shall not be affected.
Warranty Disclaimer – Outside United States
Although the PTFE Coated Guide Wire, hereafter referred to as “Product” has been
carefully designed, manufactured, and tested prior to sale, the Product may fail to
perform its intended function satisfactorily for a variety of reasons. The warnings
contained in the Product labeling provide more detailed information and are
considered an integral part of this Disclaimer of Warranty. Medtronic therefore
disclaims all warranties, both expressed and implied, with respect to the Product.
Medtronic shall not be liable for any incidental or consequential damages caused by any
use, defect, or failure of the Product, whether the claim is based on warranty, contract,
tort, or otherwise.
The exclusions and limitations set out above are not intended to, and should not be
construed so as to contravene mandatory provisions of applicable law. If any part or
term of this Disclaimer of Warranty is held to be illegal, unenforceable, or in conflict
with applicable law by a court of competent jurisdiction, the validity of the remaining
portions of this Disclaimer of Warranty shall not be affected and all rights and
obligations shall be construed and enforced as if this Disclaimer of Warranty did not
contain the particular part or term held to be invalid.
|
HRVATSKI
|
Žice vodilice s PTFE premazom
INFORMACIJE ZA UPORABU
Namijenjeno za uporabu s balonskim dilatacijskim kateterima
Prije uporabe pro
č
itajte ovaj dokument u cijelosti.
Opis
Žica vodilica s PTFE premazom tvrtke Medtronic izra
đ
ena je od nehr
đ
aju
ć
eg
č
elika s
PTFE premazom na vanjskoj površini. Žica vodilica ima fiksnu jezgru i fleksibilni
distalni vrh duljine 3 cm.
Napomena:
Distalni “J” vrh žice vodilice tipa “J” vra
ć
a se u odgovaraju
ć
i oblik nakon
izvla
č
enja iz drža
č
a.
Indikacije za primjenu
Za perkutano uvo
đ
enje uvodnog katetera tvrtke Medtronic u krvne žile korištenjem
standardnih perkutanih tehnika.
Kontraindikacije
Nisu poznate.
Upozorenja
Ovaj ure
đ
aj je za jednokratnu uporabu. Nemojte ponovno koristiti, pripremati
za korištenje niti sterilizirati.
Č
iš
ć
enje, dezinfekcija i ponovna sterilizacija
mogu ugroziti temeljna svojstva materijala i projektiranu namjenu, te dovesti
do kvara ure
đ
aja. Ponovno korištenje ovog ure
đ
aja predstavlja potencijalni
rizik od infekcije za pacijenta ili korisnika uslijed oneš
č
iš
ć
enja. One
č
iš
ć
enje
ure
đ
aja može prouzoro
č
iti ozljede, bolesti ili smrt pacijenta.
Ne koristite ako je pakiranje otvoreno ili ošte
ć
eno.
Mjere opreza
Prije uporabe pregledajte sve žice vodilice kako biste otkrili odvajanja obloge,
zakrivljenja i zapetljanja.
Žice vodilice, uslijed naravi svoje konstrukcije, u svom lumenu prikupljaju krv
i druge strane materije. Ove materije nije mogu
ć
e u potpunosti ukloniti ni
autoklavom niti ultrazvu
č
nim
č
iš
ć
enjem, stoga preporu
č
ujemo jednokratnu
uporabu.