OPERATING INSTRUCTIONS
19
−
The charger identifi es the modes matching the battery type. Therefore, not every
mode can be selected for each battery.
−
Once a mode has been selected, it will begin charging. If a battery remains
connected to the charger after it has been completely recharged, the charger
automatically switches to trickle charging. The battery continues to be trickle
charged even if a different mode is selected.
Status displays
•
If the charger has been switched on, the background illumination is blue.
•
During the charging operation, the selected charging mode, the current battery
voltage and the charging status of the battery are displayed.
•
In case of faulty operation (e.g. resulting from overheating or electric short circuit),
fault symbols are displayed, and the appliance switches to stand-by mode if
necessary.
LED
Mode
6 V / 0.8 A
standard charging mode:
Charging operation for 6 V battery
Recommended battery capacity 1.2 to 14 Ah, charging current 0.8 A and 3.8
A
12 V / 0.8 A
standard charging mode:
Charging operation for 12 V motorcycle battery or 12 V motor vehicle battery
Recommended battery capacity 1.2 to 120 Ah, 0.8 A charging current
12 V / 3.8 A
rapid charging mode:
Rapid charging operation for 12 V motor vehicle battery
Recommended battery capacity 1.2 to 120 Ah, 3.8 A charging current
12 V / 3.8 A COLD
rapid charging mode: Rapid charging operation
at low ambient temperature only for 12 V battery
Recommended battery capacity 1.2 to 120 Ah, 3.8 A charging current
/
Charging status: Battery symbol outline fl ashing, 1 to 5 bars are displayed:
Charging operation active
Charging status: 5 bars are displayed, frame is illuminated continuously:
The battery is fully charged.
Trickle charging with fully charged battery.
Fault: Battery faulty
Fault: incorrectly connected terminals
Fault: no battery connected, short circuit