Page 19
MD 1772LB (B1770NSL/T)
MEDION
Figure 4-1. Convergence Magnets on the CRT
+
8 7 6 5 4
3
2
1 0
1
1 1
C R T
F R O N T
P
9
1) Setup Bolt
2 ) B o w M ag n e t
3) Band
4) 2-Pole Magnet
5) Spacer
7) Spacer
9) Holder
6) 4-Pole Magnet
8) 6-Pole Magnet
11) Tabs
10) Band
3. Rotate the individual rings of 4-pole convergence magnets by changing the spacing between the 2 tabs to
converge the vertical red and blue lines at the center of the screen.
4. Rotate the pair of rings of 4-pole convergence magnets by maintaining spacing between the 2 tabs to
converge the horizontal red and blue lines at the center of the screen.
5. Rotate the individual rings of 6-pole convergence magnets by changing the spacing between the 2 tabs to
converge the vertical red, blue and green lines.
6. Rotate the pair of rings of 6-pole convergence magnets by maintaining spacing between the 2 tabs to
converge the horizontal red, blue and green lines.
7. Repeat the steps from 3~6 until the best convergence is obtained.
Note :
The 4-pole magnets and the 6-pole magnets interact, making dot movement complex.
Blue Red
Blue
Red
Red/
Blue G reen
Red/
Blue
G reen
4-p o le m ag n e ts
m o vem en t
6-p o le m ag n e ts
m o vem en t
Figure 4-2. 4-pole and 6-pole Magnets Movement