Machine must be handled only by an authorised technician.
ATTENTION: when the casing is dismantled active parts of the device become
accessible.
Dismantling for
installation
Assembly.
Means for disconnection with contact separations of at least 3 mm (0.12”) must
be incorporated in the fixing. These disconnection means must be incorporated
into the fixed installation.
During the installation process, the protection areas should be considered
according to standard VDE 0100. The hair dryer must be installed against a
solid surface only (wall, partition, or similar).
INSTALLATION
Unscrew the two lock screws with
the special wrench.
Remove the cover, taking care not
to knock the equipment inside.
Handle the cover with care.
Mounting is done by using concealed wiring.
Put the wiring through before tightening up the base on
the wall.
Use the template provided for wall fixing.
Drill 4 holes with diameter of 8 mm (5/16”), taking care to
clean the dust away.
Screw the base firmly to the wall using a 6-7 mm (1/4”)
flat-ended screwdriver.