background image

TROUBLESHOOTING

If the device does not work properly, first check whether you are able to rectify the problem 
yourself. If the problem cannot be solved with the steps listed, contact the customer service 
department.

 
Do not attempt to repair an electrical device yourself!

DISPOSAL

Dispose of the packaging material in an environmentally friendly manner so that it can 
be recycled. 
 

 This device is governed by the European Directive 2012/19/EU on waste electrical 
and electronic equipment (WEEE). Do not dispose of this device as normal domestic 
waste, but rather in an environmentally friendly manner via an officially approved waste 
disposal company

Problem

Possible Cause

How to Fix

The device does not work.

The device is not supplied 
with power.

Check For:
•   The  I/O button (12) has been pressed and the 

control lamp (19) is lit.

•  All cables are correctly connected to each 

other.

•  The main adapter is plugged in the plug socket 

or the car adapter is plugged in the cigarette 
lighter.

•  The plug socket or the cigarette lighter is 

defective.

•  The fuse of the main connection is inserted

The device is overheated. 
The device was in 
operation several times in 
succession / for too long.

Disconnect the main connection and allow the 
device to cool down. Always disconnect the 
device from the main when it is not in use.

The device makes noises.

Operating noises are a normal consequence of the mechanics and not a defect.

Содержание CF-2408

Страница 1: ... COOLING WARMING MASSAGING CUSHION User Manual Prior to first use be sure to read all user safety and care instructions found in this manual Please keep for reference 3D COOLING WARMING MASSAGING CUSHION ...

Страница 2: ...le Only use the main adapter or car adapter that is supplied with the device Do not use the main adapter or car adapter supplied with another device The device may not be used by people who are insensitive to heat or cold and may not be used by other vulnerable people who are unable to react to overheating or undercooling Do not use the device if it is wet or damp It must be completely dry before ...

Страница 3: ... consult a doctor Do not use the device on swelling or sore areas of skin The device may only be used by people who are able to handle the controller WARNING DANGER OF FIRE Do not use the device in rooms containing easily ignitable or explosive substances Never operate the device in the vicinity of a gas source Keep the device and accessories away from fire and other heat sources NOTICE Risk of Da...

Страница 4: ... 18 1 Back surface 2 Cooling surface on back 3 Vibrating surface on right 4 Heating surface 5 Controller 6 Cooling surface on seat 7 Fastening strap 8 Seat surface 9 Connecting cable between back and seat surface 10 Vibrating surface on left 11 Fastening straps on the back 12 I O Activate deactivate the device 13 Vibration on off 14 Cooling on off 15 Heat on off 16 Control lamp lights up when the hea...

Страница 5: ...r high heat Press twice for low heat Press a third time to turn heating function off If the button 14 is pressed once the cooling switches on at the highest level There are five cooling levels Each further press of the button switches the cooling to a lower level until it is switched off entirely NOTE The heating and cooling functions cannot be switched on at the same time The vibration and heatin...

Страница 6: ... W Protection class III Car adapter Input output voltage 12 14 V DC Fuse 3A Main adapter Model number IVP 1200 1500 Input 100 240 V 50 60 Hz max 0 5 A Output 12 V DC 1 5 A Protection class II Ø effi ciency in operation 82 82 Effi ciency on low load 25 76 93 Power consumption on no load 0 045 W ...

Страница 7: ...a an officially approved waste disposal company Problem Possible Cause How to Fix The device does not work The device is not supplied with power Check For The I O button 12 has been pressed and the control lamp 19 is lit All cables are correctly connected to each other The main adapter is plugged in the plug socket or the car adapter is plugged in the cigarette lighter The plug socket or the cigar...

Страница 8: ...our Medic Therapeutics Product is not functioning properly please send your device to our repair center for evaluation If your product cannot be repaired or serviced we will reserve the right to change it for a similar or newer model Please note that a flat rate of 35 00 will be charged to cover a service evaluation fee and return shipping of your device All warranty claims must be accompanied by ...

Отзывы: