MS9400 HD FrEND User Guide
Chapter 7: Using the GPIO Interface
46 Rev.
1.54
Option 1 – Input switch contacts using the MS9400’s power supply. This method is useful in applications where
the current required is within the allowable limit of the MS9400. 500mA is available for external use.
Option 2 – Input switch contacts using an external power supply. The voltage of the external supply is not critical
if the current through the internal 560ohm resistor is limited between 5 – 20mA. This method is preferred where
installation takes place in noisy environments, or where the switch contacts wiring is run over a long distance.
NOTE: It is imperative that the ground connection of the external PSU is connected to the ground terminal
on the FrEND.
Relay Changeover contacts (Digital Outputs)
GPIO output offers four (4) normally open/normally closed (NO/NC) sets of relay changeover contacts.
These relay outputs are used as switches to control external devices. Their activity is controlled by the GPIO
control sequence (macro) stored on the HD FrEND.