background image

P/N

323103072   VER

001

www.getmedcheck.com

Содержание SFBG01

Страница 1: ...www getmedcheck com User Manual Bluetooth Self Monitoring Blood Glucose System Model No SFBG01...

Страница 2: ......

Страница 3: ...use properly and obtain the best test results possible please read the entire User Manual before testing This package contains 2 new AAA LR03 1 5V Alkaline batteries Insert them into SFBG01 by followi...

Страница 4: ...omponent parts by accident Keep SFBG01 Blood Glucose Meter free from dust hair etc Store the meter in its container after use If you feel you are suffering from severe dehydration stop using and consu...

Страница 5: ...03 1 5V Alkaline Batteries Do not reuse Temperature Limitation Manufacturer Follow Instructions for Use Meter only Degrees of protection provided by enclosures Serial Number Biological Risks Precision...

Страница 6: ...ing 17 Battery Installation Presetting Date and Time Quality Control of the System 20 Using Glucose Control Solution Perform the Blood Glucose Test 22 Perform the Blood Glucose Test LO and HI Readings...

Страница 7: ...s greater than 13 3 mmol L 240 mg dL mean high blood glucose hyperglycemia If you get results below 3 9 mmol L 70 mg dL or above 13 3 mmol L 240 mg dL and do not have symptoms repeat the test If you h...

Страница 8: ...trips Measuring Principle We design MEDCHECK SMBG System by using the latest biosensor technology It measures the glucose levels of the blood specimen by using a disposable dry reagent strip which can...

Страница 9: ...1 5V Alkaline Batteries Wallet Complete instructions User Manual for SFBG01 SMBG System Quick Reference Guide Note Please consult your provider local distributor for extra Blood Glucose Test Strips I...

Страница 10: ...iption LCD Screen Displays blood glucose results messages and glucose results stored in memory S Button Press to adjust settings and digits Test Strip Slot Insert test strip here M Button Press to ent...

Страница 11: ...se result in mmol L unit ketone Symbol mmol L mg dL Temperature Symbol Appears when ambient temperature exceeds operating temperature BT Symbol Appears when turn on the BT function Pre meal or Post me...

Страница 12: ...piration date printed on the vial since it may cause inaccurate results Blood Glucose Test Strips are for single use only Never reuse Keep Blood Glucose Test Strips in vial always Bending cutting or t...

Страница 13: ...ing Device It is used with sterile lancet to obtain the blood for the testing Lancets It is used with lancing device to obtain the blood for the testing Cap Depth Settings Indicator Lancet Ejector Rel...

Страница 14: ...will not affect the operation of other nearby devices Additionally other devices should not affect the use of your device Other wireless devices that are in use nearby such as a cell or mobile phone...

Страница 15: ...s user to better manage the glucose control plan and also your healthcare professional by providing data when diagnosing and prescribing Follow below steps to activate Meal Comment Function Under Stan...

Страница 16: ...ws up constantly promptly consult your physician or medical professional For users who have Type 1 diabetes there is a possibility of ketoacidosis or ketone accumulation Note For those who do not wish...

Страница 17: ...sed when batteries are replaced After batteries are replaced please reset year date and time again All batteries used must be the same type Do not mix alkaline standard carbon zinc or rechargeable cad...

Страница 18: ...enter Setting Mode Note After battery replacement meter automatically activates Setting Mode When YEAR digits flash press S button to select current year When done press M button to confirm To complet...

Страница 19: ...Code Number Setting Mode by pressing M button Follow above two steps to complete setting Setting Test Strip Code Number There are two ways to set the strip code 1 press S button for 3 seconds in stan...

Страница 20: ...ntrol solution reacts with SFTS02 Blood Glucose Test Strip Who or when to perform a control solution test Strong impact on the meter When your symptoms do not agree with the way you feel or when the r...

Страница 21: ...p vial your System is working properly Note Check the Test Strip vial for acceptable ranges for High and Low Levels Refer to Glucose Control Solution instruction before use Note To avoid contamination...

Страница 22: ...appears ambient temperature falls out of acceptable range 10 C 40 C 50 F 104 F Leave your meter in a room around 10 C 40 C 50 F 104 F for 15 minutes then repeat the test Do not artificially heat or co...

Страница 23: ...ck or calloused skin Pull the cocking handle out until it clicks Wash hands first or use an alcohol swab to wipe your finger clean Wait until your hands are totally dry Insert the test strip into the...

Страница 24: ...n for details Hold the lancing device firmly against the side of your finger tip Let go of the Release Button to take a sample With symbol on your meter is ready for use To avoid body fluid contaminat...

Страница 25: ...r blood sample on the top of the test strip Instead move the test strip close to blood sample and let collection zone automatically drink the droplet in Make sure to apply enough blood on the collecti...

Страница 26: ...and user can then move your finger away With Meal Comment Function on test result appears with flashing or symbol depending on the setting Dispose of medical waste per local regulations Glucose test r...

Страница 27: ...cemia LO reading without symptoms If you have LO test results but no symptoms of low blood glucose please consult your doctor or call your local distributor for help 2 If your test result is higher th...

Страница 28: ...Blood Glucose Meter can store up to 120 test results with date and time automatically in its memory When full the meter will replace the oldest with the latest result automatically User can also view...

Страница 29: ...roll thorough all memory sets from the latest to the oldest When done press S button to return to Standby Mode Press S and M buttons for 3 seconds the screen will show dA for confirmation Press S butt...

Страница 30: ...receive the data request from APP the screen flashes symbol and the paired Bluetooth device automatically starts downloading measured results from glucose meter if they are in an acceptable range no...

Страница 31: ...with a soft cloth dampened with alcohol or soap with water Storage and Handling Keep your meter free from dust and extreme weather Always handle your meter with care Run a quality control test after s...

Страница 32: ...om temperature between 10 C 40 C 50 F 104 F Out of this range the device just won t work Extreme humidity may affect the results A relative humidity greater than 80 may cause incorrect results Hematoc...

Страница 33: ...r Strip Meter Package with Lancets or Strips 1 L Capillary Whole Blood 30 55 2 AAA LR03 1 5V Alkaline Batteries At least 1000 measurements under Bluetooth Function OFF status Meter 8000 times 5 Years...

Страница 34: ...rofile Wireless Coexistence System requirement of the Bluetooth device Bluetooth 4 0 BLE GFSK 0 dBm 0 2Mbps The latency time is less than 0 3ms second from sender to receiver Channel Quality Driven Da...

Страница 35: ...memory If Er 2 appears constantly please contact SMARTFUTURE PTE LTD or local distributor during business hours Er 3 appears when your Test Strip does not have enough blood sample on it Repeat the te...

Страница 36: ...50 F 104 F for 15 minutes then repeat the test See Perform the Blood Glucose Test Section When appears your batteries are about to run out When appears the batteries are too weak to work Repeat the t...

Страница 37: ...cs Blood Glucose Test Strips Sold Separately 9F No 186 Jian Yi Road Zhonghe District New Taipei City Taiwan www healthandlife com tw Prinsessegracht 20 2514 AP The Hague The Netherlands Smartfuture Pt...

Страница 38: ...MDD 93 42 EEC No 68 Litanghe Road Xiangcheng Suzhou China 215131 Tel 86 512 65799308 SteriLance Medical Suzhou Inc Lancets Meets the requirement of MDD 93 42 EEC No 68 Litanghe Road Xiangcheng Suzhou...

Страница 39: ...roperly because of a defect in materials or workmanship SMARTFUTURE PTE LTD will repair the meter or replace it with a new SFBG01 Blood Glucose Meter or equivalent product free of charge The warranty...

Страница 40: ...P N 323103072 VER 001 www getmedcheck com...