© Eaton MEDC Ltd 2017

5.  CERTIFICATION/APPROVALS

Please refer to marking on the unit for specific approval details.

s 5,LISTEDFORUSEIN

#LASS$IVISION'ROUPS#$

 

USA (USL) 

Class 1, Zone 1, Groups IIA & IIB.

s 5,3TANDARDS

5,5,

s 3UITABLEFORHAZARDOUSLOCATIONlREALARMAPPLICATIONS

6.  CERTIFIED TEMPERATURE

–25°C to +55°C
–13°F to +131°F

 

 

 

 

 

 

 

 

   

 

   

 

 

   

 

 

 

   

 

   

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

Introduction

                 

 

The  DB1H  Sounder  has  been  designed  for  use  in  potentially  explosive  atmospheres  and  harsh 

environmental  conditions.  The  marine  grade  alloy  or  stainless  enclosures  are  for  use  offshore  or 

onshore, where light weight combined with corrosion resistance and strength is required.

 

The safety function of the Sounder is to provide a pre-determined audible warning sound when 
required if the correct voltage is applied to the unit. The DC version of the Sounder is designed to 
operate on a supply voltage tolerance of +/- 20%,  

Under No fault (Normal) Operating conditions the DB1 Sounder will provide an audible warning 

sound when required by the system. 

 

Under fault conditions the failure mode of the Sounder is a failure to provide an audible warning 

sound. For the failure rate associated with this failure mode please refer to the table below. 

 

Assessment of Functional Safety 

This Sounder is intended for use in a safety system conforming to the requirements of IEC61508.  

UL has conducted a Failure Modes Effect and Diagnostic Analysis (FMEDA) of the DC version of DB1H 
Sounder against the requirements of IEC 61508-2 using a Proof Test Interval of 8760hrs. 
 
The results are shown below and are based on Route 1

H

 

The Sounder is classed as a Type B device   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

7.  FUNCTIONAL SAFETY - DB1H

Содержание DB1PUL

Страница 1: ...ote that every care has been taken to ensure the accuracy of our technical manual We do not however accept responsibility for damage loss or expense resulting from any error or omission We reserve the...

Страница 2: ...s holding the cover assembly to the base Keep in a safe accessible location Twist the cover gently clockwise and anti clockwise whilst pulling it away from the unit Remove to gain access to the interi...

Страница 3: ...16 8mm 5 1 2 140mm FIXING CRS 3 1 8 79mm 6 7 8 175mm DIA 3 1 8 79mm 5 1 2 140mm FIXING CRS 6 3 4 171mm DIA 6 5 8 8 1 2 168mm 216mm 4 1 8 6 105mm 152mm 1 3 16 30mm ALL DIMENSIONS IN INCHES AND MILLIMET...

Страница 4: ...mS on 150 mS off 10000 Swedish Fire Alarm 17 Int 660 Hz 1 8 sec on 1 8 sec off 01111 Swedish Fire Alarm 18 Int 660 Hz 6 5 sec on 13 sec off 01110 Swedish Fire Alarm 19 Continuous 660 Hz 01101 Swedish...

Страница 5: ...B1 ve red and TB3 ve black tone 1 will sound Reverse the voltage so that TB3 is ve and TB1 is ve tone 2 will sound 3 3 2 Common ve Set Up Connect input wires to TB1 ve and separate ve s to TB3 and TB5...

Страница 6: ...when required if the correct voltage is applied to the unit The DC version of the Sounder is designed to operate on a supply voltage tolerance of 20 Under No fault Normal Operating conditions the DB1...

Страница 7: ...IL 1 1oo1 SIL 2 1oo2 Random hardware failures h 1 DD DU 6 45E 09 8 87E 08 6 45E 10 8 87E 09 Random hardware failures h 1 SD SU 0 00E 00 1 59E 07 0 00E 00 1 59E 08 PFD PTI 8760Hrs MTTR 8 Hrs 3 89E 04 3...

Страница 8: ...ommendations in the user documentation 3 All information associated with any field failures of th dependability management process e g IEC 60300 3 2 an 4 f The unit should be tested at regular interva...

Отзывы: