~ 6 ~
2.2)Immerse the pump in the liquid to be sucked, by making an angle of 45 degrees (to reduce the amount of
air trapped in the pump body). If the pump rests on the bottom, make sure it is on a flat and stable surface.
2.3)Make sure that no one is present in the liquid to be pumped
2.4) Plug the pump to the mains
3.WORKING PRINCIPLES&TECHNICAL SPECIFICATIONS
MC *** E (_M)
Model
MC 250 E,
MC 250 E_M
MC 400 E,
MC 400 E_M
MC 500 E,
MC 500 E_M
MC 650 E,
MC 650 E_M
MC 750 E,
MC 750 E_M
MC 900 E,
MC 900 E_M
Power
250 W
400 W
500 W
650 W
750 W
900 W
Flow
7500 l/h
11500 l/h
13200 l/h
13200 l/h
15900 l/h
17200 l/h
Head
4.5 m
6.3m
6.6m
7.6m
8.5m
8.9m
Max.Depth 7m
7m
7m
7m
7m
7m
Outlet
G1-1/4
G1-1/4
G1-1/4
G1-1/4
G1-1/4
G1-1/4
Solid max.
diameter
3mm;
25mm
3mm;
25mm
3mm
30mm
23mm;
30mm
3mm;
30mm
3mm;
30mm
IP
IPX8
IPX8
IPX8
IPX8
IPX8
IPX8
Weight
3.6kg
3.8kg
4.0kg
4.2kg
4.4kg
4.8kg
4. ACCESSORIES
Connector: 1pc +Universal Fitting: 1pc+ O-ring: 2pcs OR Hose adapter 1pc
Manual: 1pc
5. USE AND DESTINATION OF THE PUMP
Your pump is designed for domestic use. It can be used to remove or transferring.
Your pump must not be used in following situations:
- Water temperature to be sucked > 35°C
- Drinking water supply or washing machines for dishes supply
- Corrosive, easily combustible, aggressive or explosive liquids (such as gasoline, petroleum or nitro thinner),
saltwater, oils and greases must not be pumped
- Permanent submersion under 3 meters or more water
6. CARE & MAINTENANCE
- In case of temporary installation, the pump must be cleaned up with clear water after use.
△
!
Electric danger
Unplug the pump before any intervention