Medas MC 250 E Скачать руководство пользователя страница 2

 

~ 2 ~

 

 

 

Summary 

Content 

 

 
1. SECURITY INSTRUCTIONS FOR YOUR SAFETY AND THE GOOD USE OF 
PUMP .....................................................................................................2   
a)SAFETY .............................................................................................2   
b) PUMP ENVIRONMENT .....................................................................2   
c) ELECTRICSAFETY ...........................................................................3 
d) PERSONAL SAFETY ........................................................................3   
2. GETTING STARTED .........................................................................4 
3. WORKING PRINCIPLES&TECHNICALSPECIFICATION

S

...............4 

4. ACCESSORIES .................................................................................5 
5. USE AND DESTINATION OF THE PUMP ........................................5 
6. CARE & MAINTENANCE ..................................................................5 
7. TROUBLESHOOTING ......................................................................6 
8. CERTIFICATE OF CONFORMITY ....................................................7 
9. GUARANTEE .....................................................................................7 
10.EXPLOSIVE DRAWING ....................................................................9 
 
 

1. 

SECURITY INSTRUCTIONS FOR YOUR SAFETY AND THE GOOD USE OF THE PUMP 

 

 

a) SAFETY 

 

a)  PERSONAL SAFETY 

This pump is not intended for use by persons (including children) with reduced physical, sensory or 
mental capabilities, or lack of experience and knowledge, unless they have been given supervision. 
Children being supervised not to play with the appliance(For NON-EU market only) 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, 
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or 
instruction concerning use of the appliance in a safe way and understand the hazards involved. Children 
shall not play with the appliance. Cleaning and user maintenance shall not be made by children without 
supervision. (For EU market only) 

If supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified 
persons in order to avoid hazard. 

The pump must to be supplied through a residual currentdevice (RCD) having a rated residual operating 

current not exceeding 30 mA. 

IMPORTANT:

for your safety, read the instructions.

 

 

Содержание MC 250 E

Страница 1: ...hose instructions are for your safety Read carefully before use and keep them MC 250 E MC 250E_M MC 400 E MC 400 E_M MC 500 E MC 500E_M MC 650 E MC 650 E_M MC 750 E MC 750E_M MC 900 E MC 900 E_M INFOR...

Страница 2: ...iven supervision Children being supervised not to play with the appliance For NON EU market only This appliance can be used by children aged from 8 years and above and persons with reduced physical se...

Страница 3: ...k of electric shock Avoid body contact with earthed or grounded surfaces from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock WARNING Inadequate ext...

Страница 4: ...d The temperature of the liquid must not exceed 35 C Do not use the pump if safety devices are damaged or depleted Never deactivate safety devices d PUMP ENVIRONMENT dust Keep children and unqualified...

Страница 5: ...must be disposed of in accordance with local environmental regulations Conformity with safety rules applicable in the EU market Read the instructions before use 1 To be checked before you start Pumps...

Страница 6: ...1 1 4 G1 1 4 G1 1 4 Solid max diameter 3mm 25mm 3mm 25mm 3mm 30mm 23mm 30mm 3mm 30mm 3mm 30mm IP IPX8 IPX8 IPX8 IPX8 IPX8 IPX8 Weight 3 6kg 3 8kg 4 0kg 4 2kg 4 4kg 4 8kg 4 ACCESSORIES Connector 1pc Un...

Страница 7: ...or the discharge pipe is too narrow Eliminate the reason for blocking Replace the impeller Clean the pump inlet Use the pump in accordance with its technical capabilities Increase the pipe diameter Th...

Страница 8: ...014 30 EU Directive ROHS 2011 65 EU Tests executed in accordance with following regulations EN55014 1 2006 A1 A2 EN55014 2 1997 A1 A2 EN60335 1 2012 A11 A13 EN60335 2 41 2003 A1 A2 EN61000 3 2 2006 A1...

Страница 9: ...y the warranty if these parts are supplied with the pump Rope suspension fitting A repair or exchange with a new product during the warranty period does not extend the original warranty period Managem...

Отзывы: