SAFETY
INFORMATION

 WARNINGS

IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, oper-
ate, or service this heater. Im-
proper use of this heater can
cause serious injury or death from
burns, fire, explosion, and car-
bon monoxide poisoning.

Carbon Monoxide Poisoning:

 Early signs

of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, and/or nau-
sea. If you have these signs, the heater may
not be working properly. Get fresh air at
once!
 Have heater serviced. Some people
are more affected by carbon monoxide than
others. These include pregnant women,
people with heart or lung disease or anemia,
those under the influence of alcohol, and
those at high altitudes.

Propane/LP Gas:

 

Propane/LP gas is odor-

less. An odor-making agent is added to pro-
pane/LP gas. The odor helps you detect a
propane/LP gas leak. However, the odor added
to propane/LP gas can fade. Propane/LP gas
may be present even though no odor exists.

Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this heater.

 DANGER: Carbon monoxide

poisoning may lead to death!

 WARNING: Any change to

this heater or its controls can be
dangerous.

1.

This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.

2.

Do not place propane/LP supply tank(s)
inside any structure. Locate propane/
LP supply tank(s) outdoors.

3.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do

not use any phone in your building

• immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions

• if you cannot reach your gas supplier,

call the fire department

4.

This heater needs fresh, outside air ven-
tilation to run properly. This heater has
an oxygen depletion sensor (ODS) pilot
light safety system. The ODS shuts
down the heater if not enough fresh air
is available. See Fresh Air for Combus-
tion and Ventilation,
 pages 4 through 6.

5.

Keep all air openings in the front and
bottom of heater clear and free of de-
bris. This will insure enough air for
proper combustion.

6.

If heater shuts off, do not relight until
you provide fresh, outside air. If heater
keeps shutting off, have it serviced.

7.

Do not run heater
• where flammable liquids or vapors

are used or stored

• under dusty conditions

8.

Do not use heater if any part has been
under water. Immediately call a quali-
fied service technician to inspect the
room heater and to replace any part of
the control system and any gas control
which has been under water.

9.

Turn off heater and let cool before ser-
vicing. Only a qualified service person
should service and repair heater.

10. Operating heater above elevations of

4,500 feet could cause pilot outage.

11. To prevent performance problems, do

not use propane fuel tank of less than
100 lbs. capacity.

12. Do not install model MBP10LA in a

bathroom.

13. Before using furniture polish, wax, car-

pet cleaner, or similar products, turn
heater off. If heated, the vapors from
these products may create a white pow-
der residue within burner box or on
adjacent walls or furniture.

Do not place clothing or other
flammable material on or near
the appliance. Never place any
objects on the heater.

Surface of heater becomes very
hot when running heater. Keep
children and adults away from
hot surface to avoid burns or
clothing ignition. Heater will re-
main hot for a time after shut-
down. Allow surface to cool be-
fore touching.

Carefully supervise young chil-
dren when they are in the same
room with heater.

Make sure grill guard is in place
before running heater.

Keep the appliance area clear and
free from combustible materials,
gasoline and other flammable
vapors and liquids.

Due to high temperatures, the
appliance should be located out
of traffic and away from furniture
and draperies.

 WARNING: Do not use any

accessory not approved for use
with this heater.

Содержание MBP10LA

Страница 1: ...adequate com bustion and ventilation air must be provided Refer to Air For Combustion and Ventila tion on page 4 of this manual 10 000 and 6 000 Btu Hr Manually Controlled Models WARNING Improper ins...

Страница 2: ...n oxygen depletion sensor ODS pilot light safety system The ODS shuts down the heater if not enough fresh air is available See Fresh Air for Combus tion and Ventilation pages 4 through 6 5 Keep all ai...

Страница 3: ...al Fire Protection Association Inc Batterymarch Park Quincy MA 02269 UNPACKING 1 Remove heater from carton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any ship...

Страница 4: ...ustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings ex...

Страница 5: ...uel burning appliances in the space Vent free heater ______________ Btu Hr Gas water heater ______________ Btu Hr Gas furnace ______________ Btu Hr Vented gas heater ______________ Btu Hr Gas fireplac...

Страница 6: ...PA 54 ANS Z223 1 Section5 3 AirforCombustionand Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermos...

Страница 7: ...sory page 18 LOCATING HEATER This heater is designed to be mounted on a wall WARNING Maintainthemini mumclearancesshowninFigure 4 Ifyoucan providegreaterclear ances from floor ceiling and joining wall...

Страница 8: ...s ANCHOR Figure 8 Tightening Anchors Thin or Thick Wall thick wall shown Solid Wall 1 16 Space Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place...

Страница 9: ...from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly Installationmustincludeaequipmentshutoff valve ground joint union and plugged 1 8 NP...

Страница 10: ...opane LP supply tank valve 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and wa...

Страница 11: ...f control knob does not pop up when released contact a qualified service person or gas supplier for repairs 6 With control knob pressed in push down and release ignitor button This will light pilot Th...

Страница 12: ...LOT FLAME PATTERN Figure 18 shows a correct pilot flame pat tern Figure 19 shows an incorrect pilot flame pattern The incorrect pilot flame is not touching the thermocouple This will cause the thermoc...

Страница 13: ...maged OBSERVED PROBLEM When ignitor button is pressed there is no spark at ODS pilot When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when...

Страница 14: ...em will stop after a few hours of operation 1 Turn control knob to LOW position and let warm up for a minute 2 Operate burner until air is removed from line Have gas checked by local propane LP gas co...

Страница 15: ...burning vapors from paint hair spray glues etc See IMPORTANT statement above 2 Low fuel supply 3 Gas leak SeeWarning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3...

Страница 16: ...16 105716 PROPANE LP GAS HEATER MBP10LA AND MBP6LA MBP10LA MBP6LA 12 2 12 1 ILLUSTRATED PARTS LIST 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 17 18 21 22 25 20 24 23 19 26 27 16...

Страница 17: ...01 098249 01 Nut M5 2 12 099059 03 099059 03 ODS Pilot Assembly 1 12 1 098514 01 098514 01 Thermocouple 1 12 2 098594 01 098594 01 Ignitor Electrode 1 13 104263 02 104263 01 Burner 1 14 099387 05 099...

Страница 18: ...ctory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they cannot supply original replacement part s contact Cans Unlimited Incorporated s Parts Department at 1 800 922 7407 for...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...ns furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents...

Отзывы: