Test the potentiometer and adjust the squirt position: 

 

 

 

 

 

 

 

 

 

P1  left  and  right  potentiometer:  this  item  is  to  test  the  left  and  right 

potentiometer.    When move the squirt gun left and right, the value will change, 

if  it  is  not  change,  it  means  the  left  and  right  potentiometer  is  not  working 

properly. 

P1  up  and  down  potentiometer:  this  item  is  to  test  the  up  and  down 

potentiometer.    When move the squirt gun up and down, the value will change, 

if  it  is  not  change,  it  means  the  up  and  down  potentiometer  is  not  working 

properly. 

P1  coordinate correction:  this  item  is  to  correct  the  coordinate  when  it  is  not 

accurate. 

Exit: Exit potentiometer setting. 

 
Move the squirt gun to the aiming point, press the start button. 

 

 

 

1到

退

:YES

P1屏

:1

P1上

:98

P1左

:218

Содержание Kiddie Firemen

Страница 1: ...Kiddie Firemen Operation manual...

Страница 2: ...game door unless maintenance or parts replacement is required 2 Please switch off the power before checking and maintenance 3 Please switch off the power before opening the game door 4 Fire extinguish...

Страница 3: ...kage 3 To put the machine to normal operating please properly adjust the coin match and the game settings when use at the first time 4 Please regularly check all the functions of the game when operate...

Страница 4: ...t use the following cleanser Alterative Cleanser Acidic Cleanser Insecticide sterilized water alcohol or other chemical cleanser Notes of Moving and Shipping 1 Properly disassemble the game for necess...

Страница 5: ...ene such as water cannons water tank and fire extinguisher 4 Game over when the playing time countdown to 0 2 TECHNICAL PARAMETER VOLTAGE AC 220V 110V 50 60HZ MAX CURRENT 8A 15A Note please refer to t...

Страница 6: ...ation to leave the ground about 5mm WARNING Please power off the game first and pull out the cord then move the game Please do not carefully move turnover transport the game otherwise it will destroy...

Страница 7: ...men in the same type of Kiddie Ride with monitor then select the concrete placement machine according to the machine s exterior 2 Choose the proper location for installation please follow the below dr...

Страница 8: ...7 7 4 2 FIX THE FOUNDATION Screw the foundation down to hold the game distance between ground and wheel is 1cm 4 3 ADD WATER As shown below Add about 50L clean water 1cm Foundation Wheel Add water he...

Страница 9: ...the both ends for GND is more than 100 megohm 4 Connect the wires Attention A Please make sure the power cord is not pressed by wheel foundation etc Otherwise it will damage the wire to cause short ci...

Страница 10: ...please switch on the game 3 Inserting coin to check if the coin machine cans work properly 4 Visually check the game and confirm the display and light can work properly 5 Enter into the setting progr...

Страница 11: ...sually check the game and confirm the display can work properly 3 Check the sound if it is ok 4 Confirm the coin mech button and the squirt is working properly Warning Before operation please confirm...

Страница 12: ...G 1 Find out the setting board KEYS FOR SETTING TEST Enter into the setting menu or skip to the next menu ENTER Change the setting SERVE 1 free play Setting board SW1 TEST SERVE SELECT ENTER ERASE Set...

Страница 13: ...how many scores to get 1 ticket Standby music this setting decides if play music when the game is standby Ticket out this setting can decide if to payout ticket not opened yet Volume this setting is...

Страница 14: ...tentiometer is not working properly P1 up and down potentiometer this item is to test the up and down potentiometer When move the squirt gun up and down the value will change if it is not change it me...

Страница 15: ...he adjusting switch of COIN Signal wave length to 50MS 5 Adjust the micro adjusting resistance of token tolerance Clockwise increasing the sensitivity of token tolerance that is the range of accepting...

Страница 16: ...entiometers are working properly but the squirt coordinate is not accurate please select P1 coordinate correction to correct it 4 When the coordinate at the upper left corner move the squirt gun to th...

Страница 17: ...erly SOUND Check whether the sound and volume are ok PUMP Check if the pump works properly TEMPERATURE HUMIDITY Check if the temperature and humidity is proper Daily Maintenance ITEM DESCRIPTION Perio...

Страница 18: ...gulating valve 1 then the pump is energized and run and drain the water to the bucket 3 After drained the water please close the drain value and add clean water 50 L to the game 4 Open the water press...

Отзывы: