Vortex
-dV
Operating Manual
Mecmesin
20
5.
Vortex-dV Settings
Settings: Jog settings
Within the jog settings menu, you can configure the jog speed limits while in jog mode.
Below is a detailed breakdown of each setting and the options available for each setting.
Setting
Action
Range
Clockwise Speed
Configure the jog speed in a clockwise direction
0.1 to 30
rev/min
Anticlockwise
Speed
Configure the jog speed in an anticlockwise direction
0.1 to 30
rev/min
Clockwise Limit
Configure the clockwise torque limit while in jog mode
0 to 10 N.m
Anticlockwise
Limit
Configure the anticlockwise torque limit while in jog
mode
0 to 10 N.m
Tare AFTI
Configure whether or not the AFTI is tared when pressing
the tare button in jog mode.
Yes or No
Settings: Units
Within the units menu, you can configure the test stands units for displacement and
speed. Torque settings are configured using the AFTI.
Setting
Units Available
Angle
rev, deg
Speed
rev/min, rev/sec, deg/min, deg/sec
Torque
N.m, N.cm, mN.m, gf.cm, kgf.cm, kgf.m, lbf.ft, lbf.in, ozf.in