Mechatronics Eurosens Delta CAN 250 Скачать руководство пользователя страница 8

EUROSENS

 

Fuel

 

flow

 

meters.

 

Operation

 

manual.

 

ver.

 

1.6

 

 

www.mechatronics.by

                              

 

 

 

          

Page

 

8

 

|

 

30

 

 

Direct

 

model

 

flowmeters

 

were

 

intended

 

to

 

display

 

local

 

information,

 

have

 

no

 

pulse

 

output.

 

Requires

 

an

 

external

 

power

 

supply.

 

Flowmeters

 

with

 

index

 

A

 

are

 

also

 

built

 

into

 

the

 

battery

 

and

 

allow

 

the

 

meter

 

to

 

operate

 

independently

 

within

 

three

 

years.

 

Direct

 

Consumption

 

Indicators

 

A

 

single

 

me

 

of

 

the

 

full

 

range

 

of

 

blade

 

switches

 

function

 

instead

 

of

 

the

 

Hall

 

sensor,

 

which

 

is

 

caused

 

by

 

considerations

 

of

 

minimal

 

power

 

consumption.

 

Direct

 

consumption

 

indicators

 

PN

 

A

 

I

 

can

 

be

 

powered

 

either

 

by

 

external

 

power

 

supply

 

and

 

the

 

internal

 

battery.

 

Have

 

a

 

pulse

 

output

 

and

 

display.

 

Table

 

5.

 ‐ 

continue

 

Eurosens

 

flow

 

meters

 

Qstart,

 

liters/hour

Qmin,

 

liters/hour

Qnom,

 

liters/hour

Qmax,

 

liters/hour

 

Amount

 

pulses/liter

 

Accuracy

 

Delta

 

PN

 

100

 

0,5

 

10

 

50

 

100

 

200

 

±

 

1,2%*

 

Delta

 

PN

 

250

 

0,5

 

20

 

125

 

250

 

100

 

±

 

1,2%**

 

Delta

 

PN

 

500

 

1,0

 

40

 

250

 

500

 

50

 

±

 

1,5%***

 

Delta

 

PN

 

100

 

I

 

0,5

 

10

 

50

 

100

 

200

 

±

 

1,2%*

 

Delta

  

PN

 

250

 

I

 

0,5

 

20

 

125

 

250

 

100

 

±

 

1,2%**

 

Delta

  

PN

 

500

 

I

 

1,0

 

40

 

250

 

500

 

50

 

±

 

1,5%***

 

Delta

 

PN

 

A

 

100

 

I

 

0,5

 

10

 

50

 

100

 

200

 

±

 

1,2%*

 

Delta

 

PN

 

A

 

250

 

I

 

0,5

 

20

 

125

 

250

 

100

 

±

 

1,2%**

 

Delta

 

PN

 

A

 

500

 

I

 

1,0

 

40

 

250

 

500

 

50

 

±

 

1,5%***

 

Flows

 

to

 

supply

 

/

 

consumption

 

in

 

liters

 

/

 

hour:

 

*

 

45/10

 

**

 

90/20

 

***

 

160/30

 

 

A

 ‐ 

autonomous

 

counter,

 

built

in

 

battery

 

power

 

I

‐ 

integrated

 

LCD

 

display

 

PN

 ‐ 

Normalized

 

pulse.

 

Processor

 

built

in.

 

 

The

 

Eurosens

 

Delta

 

Differential

 

Thesaurus

 

has

 

the

 

following

 

unique

 

characteristics:

 

1.

 

Payment

 

fuel

 

temperature

 

differs

 

in

 

both

 

chambers.

 

2.

 

The

 

use

 

of

 

Hall

 

sensors

 

provides

 

high

 

reliability

 

and

 

resistance

 

to

 

the

 

external

 

magnetic

 

field.

 

3.

 

Materials

 

High

 

quality

 

camera

 

and

 

machining

 

allows

 

you

 

to

 

set

 

a

 

3

 

year

 

warranty

 

period

 

without

 

limiting

 

the

 

camera

 

resource.

 

4.

 

Ability

 

to

 

add

 

fuel

 

flow

 

instead

 

of

 

subtraction.

 

5.

 

Measuring

 

not

 

only

 

the

 

fuel

 

consumption,

 

but

 

also

 

the

 

operating

 

timer,

 

and

 

the

 

operating

 

time

 

and

 

fuel

 

consumption

 

in

 

the

 

partial

 

engine

 

operating

 

modes,

 

which

 

are

 

set

 

limit.

 

Table

 

5.

 ‐ 

continue

 

Eurosens

 

flow

 

meters

 

Qstart,

 

liters/hour

Qmin,

 

liters/hour

Qnom,

 

liters/hour

Qmax,

 

liters/hour

 

Amount

 

pulses/liter

 

Accuracy

 

Direct

 

RS

 

100

 

0,5

 

1

 

50

 

100

 

200

 

±

 

1%

 

Direct

 

RS

 

250

 

0,5

 

2

 

125

 

250

 

100

 

±

 

1%

 

Direct

 

RS

 

500

 

1,0

 

5

 

250

 

500

 

50

 

±

 

1%

 

Direct

 

CAN

 

100

 

0,5

 

1

 

50

 

100

 

200

 

±

 

0,5%

 

Direct

 

CAN

 

250.05

 

0,5

 

2

 

125

 

250

 

100

 

±

 

0,5%

 

Содержание Eurosens Delta CAN 250

Страница 1: ...phone 375 1771 7 13 00 e mail office mechatronics by Eurosens flowmeters operation manual...

Страница 2: ...selection 5 2 5 Dimensions 6 2 6 Specification 6 2 7 Contents of package 10 2 8 Flow meter design and operation 11 3 WARRANTY 15 4 INSTALLATION RECOMMENDATIONS FOR EUROSENS FLOWMETER 16 4 1 Visual ins...

Страница 3: ...their operating features The sources of danger during the installation and operation of the flow sensors are electrical current and working fluid which can be pressurized to 2 5 MPa and have temperat...

Страница 4: ...nnormalized pulse only for Direct possible 100 No symbol LCD is not installed Direct 1 PN normalized pulse No symbol not possible 250 232 normalized pulse RS232 interface 500 485 normalized pulse RS48...

Страница 5: ...with the safe operation of the Eurosens sensors on petrol engines are assigned to the installer of the equipment Fuel flowmeters Eurosens Direct Delta N RS is a unique equipment that allows to set ind...

Страница 6: ...commended to install the flowmeter when there is an air in the supply or return line and also in the fuel system with high capacity pomp when the fuel consumption is not large 2 5 Dimensions See para...

Страница 7: ...easure not only the fuel consumption but also the derived parameters the engine is running boiler the fuel consumption and the operating time in different modes during the handling etc These parameter...

Страница 8: ...50 1 5 Delta PN A 100 I 0 5 10 50 100 200 1 2 Delta PN A 250 I 0 5 20 125 250 100 1 2 Delta PN A 500 I 1 0 40 250 500 50 1 5 Flows to supply consumption in liters hour 45 10 90 20 160 30 A autonomous...

Страница 9: ...lta CAN 250 0 5 20 125 250 100 1 2 Delta CAN 500 1 0 40 250 500 50 1 5 Delta CAN 100 I 0 5 10 50 100 200 1 2 Delta CAN 250 I 0 5 20 125 250 100 1 2 Delta CAN 500 I 1 0 40 250 500 50 1 5 Flows to suppl...

Страница 10: ...5 Vibration resistance Max acceleration to 100 m s2 in the frequency range from 5 to 250 Hz Resistance to aggressive environments Oil and petrol resistance Electromagnetic compatibility ECE Regulation...

Страница 11: ...number of dimensions of the cover and the housing which provides the optimum rotation of the ring chamber During one rotation of the piston volume of liquid equal to the volume of chamber is displace...

Страница 12: ...eat volume of return chamber l Return flow rate l h Temperature in return chamber C Battery charge Firmware version These parameters plus some additional are also displayed in configuration software o...

Страница 13: ...ave holes for sealing that allows to determine the facts of unauthorized interference in the fuel system after the installation of the flow sensor 2 8 5 Characteristics of the pulse signal of Eurosens...

Страница 14: ...PH 500 0 9Ubat 0 7 V Direct PN A 100 0 7 Ubat 0 4 1 4 V Direct PN A 250 0 7 Ubat 0 4 1 4 V Direct PN A 500 0 7 Ubat 0 4 1 4 V Delta PN A 100 0 6 Ubat 0 8 0 7 V Delta PN A 250 0 6 Ubat 0 8 0 7 V Delta...

Страница 15: ...ents provided that storage transport and operation conditions are observed and also the instructions for use that set out in this technical requirement are observed as well 2 Product warranty period 3...

Страница 16: ...cle condition should be estimated to make a conclusion regarding installation possibility Table 12 Sequence of actions Action Normal state Recommendations in case of mismatch condition 1 To inspect th...

Страница 17: ...of capacity of the pomp that is installed at the vehicle or by experimental method by connection of fuel flowmeter with display for example Direct PN A I to the scheme 2 It is not recommended to inst...

Страница 18: ...t be protected from external destructive effects 6 It is not allowed to reduce the internal cross section of the fuel lines on the bends 7 Fuel hoses on the vehicle must be fixed every 0 5 m 8 Fuel ho...

Страница 19: ...the engine Excess fuel from the fuel pump and injectors of the engine is discharged back into the tank through relief valve 4 4 2 Installation of fuel flow meters Eurosens Direct On pressure side sch...

Страница 20: ...the amount of fuel which is consumed by engine Advantages of the scheme on pressure side Eurosens Direct is set after the regular fuel fine filter Reduced flow resistance on the supply pump suction si...

Страница 21: ...Thus to the inlet of supply pump two lines are connected 1 supply from the tank passing through the flow sensor 2 The return fuel pump Thus through the flow sensor Direct goes only the amount of fuel...

Страница 22: ...ometimes it is needed to install an additional heater 4 4 4 Installation of Eurosens Delta under Differential scheme In differential scheme the measuring circuit of fuel circulating in the fuel system...

Страница 23: ...ump inlet fuel tank Fig 8 Eurosens Delta installation with supply chamber on pressure side Fig 9 Eurosens Delta installation with supply chamber on suction side Advantages of differential installation...

Страница 24: ...f the vehicle with mandatory fixing with buckles every 50 cm Make electrical connection in accordance to the passport for the product pin circuit Color wires in the cable 1 VBAT green 2 GND black 3 K...

Страница 25: ...www mechatronics by Page 25 30 It is recommended to contact Mechatronics technical support or the nearest service center all contact you can find on our web site http www mechatronics by Fig 12 Simple...

Страница 26: ...EUROSENS Fuel flow meters Operation manual ver 1 6 www mechatronics by Page 26 30 Fig 13 Simple diagnostics of the Eurosens Direct P PH PN flow meters continuation...

Страница 27: ...EUROSENS Fuel flow meters Operation manual ver 1 6 www mechatronics by Page 27 30 Fig 14 Simple diagnostics of the Eurosens Delta PN flow meters...

Страница 28: ...0 C and relative humidity up to 100 at 25 C Do not store Eurosens flow sensors in the same room with substances that cause corrosion of the metal and or contain active agents Storage life of eurosens...

Страница 29: ...eters does not contain harmful substances and ingredients that are dangerous to human health and environment during and after the end of life and recycling Eurosens fuel flow meters do not contain pre...

Страница 30: ...EUROSENS Fuel flow meters Operation manual ver 1 6 www mechatronics by Page 30 30 Fig 17 Dimensions of the EUROSENS Delta PN RS CAN F Forward supply flow R Return return flow...

Отзывы: