![Mechatronics Eurosens Delta CAN 250 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/mechatronics/eurosens-delta-can-250/eurosens-delta-can-250_operation-manual_1758992008.webp)
EUROSENS
Fuel
flow
meters.
Operation
manual.
ver.
1.6
www.mechatronics.by
Page
8
|
30
Direct
model
flowmeters
were
intended
to
display
local
information,
have
no
pulse
output.
Requires
an
external
power
supply.
Flowmeters
with
index
A
are
also
built
into
the
battery
and
allow
the
meter
to
operate
independently
within
three
years.
Direct
Consumption
Indicators
A
single
me
of
the
full
range
of
blade
switches
function
instead
of
the
Hall
sensor,
which
is
caused
by
considerations
of
minimal
power
consumption.
Direct
consumption
indicators
PN
A
I
can
be
powered
either
by
external
power
supply
and
the
internal
battery.
Have
a
pulse
output
and
display.
Table
5.
‐
continue
Eurosens
flow
meters
Qstart,
liters/hour
Qmin,
liters/hour
Qnom,
liters/hour
Qmax,
liters/hour
Amount
pulses/liter
Accuracy
Delta
PN
100
0,5
10
50
100
200
±
1,2%*
Delta
PN
250
0,5
20
125
250
100
±
1,2%**
Delta
PN
500
1,0
40
250
500
50
±
1,5%***
Delta
PN
100
I
0,5
10
50
100
200
±
1,2%*
Delta
PN
250
I
0,5
20
125
250
100
±
1,2%**
Delta
PN
500
I
1,0
40
250
500
50
±
1,5%***
Delta
PN
A
100
I
0,5
10
50
100
200
±
1,2%*
Delta
PN
A
250
I
0,5
20
125
250
100
±
1,2%**
Delta
PN
A
500
I
1,0
40
250
500
50
±
1,5%***
Flows
to
supply
/
consumption
in
liters
/
hour:
*
45/10
**
90/20
***
160/30
A
‐
autonomous
counter,
built
‐
in
battery
power
I
‐
integrated
LCD
display
PN
‐
Normalized
pulse.
Processor
built
‐
in.
The
Eurosens
Delta
Differential
Thesaurus
has
the
following
unique
characteristics:
1.
Payment
fuel
temperature
differs
in
both
chambers.
2.
The
use
of
Hall
sensors
provides
high
reliability
and
resistance
to
the
external
magnetic
field.
3.
Materials
High
quality
camera
and
machining
allows
you
to
set
a
3
year
warranty
period
without
limiting
the
camera
resource.
4.
Ability
to
add
fuel
flow
instead
of
subtraction.
5.
Measuring
not
only
the
fuel
consumption,
but
also
the
operating
timer,
and
the
operating
time
and
fuel
consumption
in
the
partial
engine
operating
modes,
which
are
set
limit.
Table
5.
‐
continue
Eurosens
flow
meters
Qstart,
liters/hour
Qmin,
liters/hour
Qnom,
liters/hour
Qmax,
liters/hour
Amount
pulses/liter
Accuracy
Direct
RS
100
0,5
1
50
100
200
±
1%
Direct
RS
250
0,5
2
125
250
100
±
1%
Direct
RS
500
1,0
5
250
500
50
±
1%
Direct
CAN
100
0,5
1
50
100
200
±
0,5%
Direct
CAN
250.05
0,5
2
125
250
100
±